SBS Cmd
Name
Access
Proto-
col
Type
Min
Max
Unit
SE
US
FA
0x1E/1F
MaxLoadCurrent()
R
Word
I2
–32767
32768
mA
12.1.17 0x20/21 MaxLoadTimeToEmpty()
This read-word function returns the predicted remaining battery capacity based on the maximum load rate of
discharge.
SBS Cmd
Name
Access
Proto-
col
Type
Min
Max
Unit
Note
SE
US
FA
0x20/21
MaxLoadTimeTimeToEmpty()
R
R
R
Word
U2
0
65535
min
65535 = Battery is not being
discharged.
12.1.18 0x22/23 AveragePower()
This read-word function returns the average power during battery charging or discharging. It is negative due to
discharge and positive due to charge. A zero value indicates the battery is not being discharged.
SBS Cmd
Name
Access
Proto-
col
Type
Min
Max
Unit
SE
US
FA
0x22/23
AveragePower()
R
Word
I2
–32767
32768
mW
12.1.19 0x28/29 InternalTemperature()
This read-word function returns the internal die temperature in units 0.1 K.
SBS Cmd
Name
Access
Proto-
col
Type
Min
Max
Unit
SE
US
FA
0x28/29
InternalTemperature()
R
Word
U2
0
65535
0.1 K
12.1.20 0x2A/2B CycleCount()
This read-word function returns the number of discharge cycles the battery has experienced.
SBS Cmd
Name
Access
Proto-
col
Type
Min
Max
Unit
SE
US
FA
0x2A/2B
CycleCount()
R
R/W
R/W
Word
U2
0
65535
cycles
12.1.21 0x2C/2D RelativeStateOfCharge()
This read-word function returns the predicted remaining battery capacity as a percentage of
FullChargeCapacity()
.
SBS Cmd
Name
Access
Proto-
col
Type
Min
Max
Unit
SE
US
FA
0x2C/2D
RelativeStateOfCharge()
R
Word
U1
0
100
%
12.1.22 0x2E/2F State-of-Health (SOH)
This command returns the state-of-health (SOH) information of the battery in percentage of design capacity. It is
a read-only command.
SBS Cmd
Name
Access
Proto-
col
Type
Min
Max
Unit
SE
US
FA
0x2E/2F
State-of-Health()
R
Word
U1
0
100
%
12.1.23 0x30/31 ChargingVoltage()
This read-word function returns the desired charging voltage.
I2C Commands
70
BQ28Z610-R2
Copyright © 2022 Texas Instruments Incorporated