IN (Bit 12)
: Charge Inhibit
1 = Active
0 = Inactive
HV (Bit 11)
: High Voltage Region
1 = Active
0 = Inactive
MV (Bit 10)
: Mid Voltage Region
1 = Active
0 = Inactive
LV (Bit 9)
: Low Voltage Region
1 = Active
0 = Inactive
PV (Bit 8)
: Precharge Voltage Region
1 = Active
0 = Inactive
OT (Bit 6)
: Over Temperature Region
1 = Active
0 = Inactive
HT (Bit 5)
: High Temperature Region
1 = Active
0 = Inactive
STH (Bit 4)
: Standard Temperature High Region
1 = Active
0 = Inactive
RT (Bit 3)
: Room Temperature Region
1 = Active
0 = Inactive
STL (Bit 2)
: Standard Temperature Low Region
1 = Active
0 = Inactive
LT (Bit 1)
: Low Temperature Region
1 = Active
0 = Inactive
UT (Bit 0)
: Under Temperature Region
1 = Active
0 = Inactive
12.2.32 MACSubcmd() 0x0056 GaugingStatus
This command returns the
GaugingStatus()
flags on
MACData()
.
Note
The
Battery Management Studio (bqStudio)
tool splits the returned value of
GaugingStatus()
into two
separate registers:
GaugingStatus
= Lowest Byte, and
ITStatus
= 2nd and 3rd bytes, with the 4th byte
reserved.
I2C Commands
SLUUCO0 – APRIL 2022
BQ28Z610-R2
85