Class
Subclass
Name
Type
Min
Max
Default
Unit
Description
Gas Gauging
Design
Design Capacity
cWh
I2
0
32767
6336
cWh
Design Capacity in cWh
Gas Gauging
Design
Design Voltage
I2
0
32767
7200
mV
Design Voltage
13.6.5 Cycle
Class
Subclass
Name
Type
Min
Max
Default
Unit
Description
Gas Gauging
Cycle
Cycle Count
Percentage
U1
0
100
90
%
Cycle Count Percentage
13.6.6 FD
Class
Subclass
Name
Type
Min
Max
Default
Unit
Description
Gas Gauging
FD
Set Voltage Threshold
I2
0
5000
3000
mV
BatteryStatus()[FD]
cell voltage set threshold
Gas Gauging
FD
Clear Voltage
Threshold
I2
0
5000
3100
mV
BatteryStatus()[FD]
cell voltage clear threshold
Gas Gauging
FD
Set RSOC %
Threshold
U1
0
100
0
%
BatteryStatus()[FD]RelativeStateOfCharge()
set
threshold
Gas Gauging
FD
Clear RSOC %
Threshold
U1
0
100
5
%
BatteryStatus()[FD]RelativeStateOfCharge()
clear
threshold
13.6.7 FC
Class
Subclass
Name
Type
Min
Max
Default
Unit
Description
Gas Gauging
FC
Set Voltage Threshold
I2
0
5000
4200
mV
BatteryStatus()[FC]
cell voltage set threshold
Gas Gauging
FC
Clear Voltage
Threshold
I2
0
5000
4100
mV
BatteryStatus()[FC]
cell voltage clear threshold
Gas Gauging
FC
Set RSOC %
Threshold
U1
0
100
100
%
BatteryStatus()[FC]RelativeStateOfCharge()
set
threshold
Gas Gauging
FC
Clear RSOC %
Threshold
U1
0
100
95
%
BatteryStatus()[FC]RelativeStateOfCharge()
clear
threshold
13.6.8 TDA
Per the
Smart Battery Data Specification v1.1
, TDA is only active while discharging.
Class
Subclass
Name
Type
Min
Max
Default
Unit
Description
Gas Gauging
TD
Set Voltage
Threshold
I2
0
5000
3200
mV
GaugingStatus[TD]
cell voltage set threshold
Gas Gauging
TD
Clear Voltage
Threshold
I2
0
5000
3300
mV
GaugingStatus[TD]
cell voltage clear threshold
Gas Gauging
TD
Set RSOC %
Threshold
U1
0
100
6
%
GaugingStatus[TD]RelativeStateOfCharge()
set
threshold
Gas Gauging
TD
Clear RSOC %
Threshold
U1
0
100
8
%
GaugingStatus[TD]RelativeStateOfCharge()
clear threshold
13.6.9 TCA
Per the
Smart Battery Data Specification v1.1
, TCA is only active while charging.
Class
Subclass
Name
Type
Min
Max
Default
Unit
Description
Gas
Gauging
TC
Set Voltage Threshold
I2
0
5000
4200
mV
GaugingStatus[TC]
cell voltage set threshold
Gas
Gauging
TC
Clear Voltage
Threshold
I2
0
5000
4100
mV
GaugingStatus[TC]
cell voltage clear threshold
Gas
Gauging
TC
Set RSOC %
Threshold
U1
0
100
100
%
GaugingStatus[TC]RelativeStateOfCharge()
set
threshold
Gas
Gauging
TC
Clear RSOC %
Threshold
U1
0
100
95
%
GaugingStatus[TC]RelativeStateOfCharge()
clear
threshold
Data Flash Values
106
BQ28Z610-R2
Copyright © 2022 Texas Instruments Incorporated