LDMD (Bit 3)
: LOAD mode
1 = Constant oower
0 = Constant current
R_DIS (Bit 2)
: Resistance updates
1 = Disabled
0 = Enabled
VOK (Bit 1)
: Voltage OK for QMax updates
1 = Detected
0 = Not detected
QMax (Bit 0)
: QMax updates. This bit toggles after every QMax update.
12.1.2 0x02/03 AtRate()
This read/write word function sets the value used in calculating
AtRateTimeToFull()
and
AtRateTimeToEmpty()
.
SBS Cmd
Name
Access
Proto-
col
Type
Min
Max
Default
Unit
SE
US
FA
0x02/03
AtRate()
R/W
Word
I2
–32768
32767
0
mA
12.1.3 0x04/05 AtRateTimeToEmpty()
This read-word function returns the remaining time to fully discharge the battery stack.
SBS
Cmd
Name
Access
Proto-
col
Type
Min
Max
Unit
Note
SE
US
FA
0x04/05
AtRateTimeToEmpty()
R
Word
U2
0
65535
min
65535 indicates not being
charged
12.1.4 0x06/07 Temperature()
This read-word function returns the temperature in units 0.1 K.
SBS Cmd
Name
Access
Proto-
col
Type
Min
Max
Unit
SE
US
FA
0x06/07
Temperature()
R
Word
U2
0
65535
0.1 K
12.1.5 0x08/09 Voltage()
This read-word function returns the sum of the measured cell voltages.
SBS Cmd
Name
Access
Proto-
col
Type
Min
Max
Unit
SE
US
FA
0x08/09
Voltage()
R
Word
U2
0
65535
mV
12.1.6 0x0A/0B BatteryStatus()
This read-word function returns various battery status information.
I2C Commands
SLUUCO0 – APRIL 2022
BQ28Z610-R2
67