The
Charging Configuration[CRATE]
flag provides an option to adjust the
ChargingCurrent()
based on
FullChargeCapacity()/DesignCapacity()
.
For example, with
[CRATE]
= 1, if
FullChargeCapacity()
/
DesignCapacity()
= 90% and
Rec Temp Charging:
Current Med
is active per the charging algorithm, the
ChargeCurrent()
=
Rec Temp Charging: Current Med
×
90%.
Note
Table priority is top to bottom.
Temp Range
Voltage Range
Condition
Action
Any
Any
OperationStatus()[XCHG]
= 1
ChargingCurrent()
= 0
UT or OT
Any
—
ChargingCurrent()
= 0
Any
PV
—
ChargingCurrent()
=
Pre-Charging:Current
Any
LV, MV, or HV
ChargingStatus()[MCHG]
= 1
ChargingCurrent()
=
Maintenance Charging:Current
LT
LV
—
ChargingCurrent()
=
Low Temp Charging:Current Low
MV
—
ChargingCurrent()
=
Low Temp Charging:Current Med
HV
—
ChargingCurrent()
=
Low Temp Charging:Current High
STL or STH
LV
—
ChargingCurrent()
=
Standard Temp Charging:Current Low
MV
—
ChargingCurrent()
=
Standard Temp Charging:Current Med
HV
—
ChargingCurrent()
=
Standard Temp Charging:Current High
RT
LV
—
ChargingCurrent()
=
Rec Temp Charging:Current Low
MV
—
ChargingCurrent()
=
Rec Temp Charging:Current Med
HV
—
ChargingCurrent()
=
Rec Temp Charging:Current High
HT
LV
—
ChargingCurrent()
=
High Temp Charging:Current Low
MV
—
ChargingCurrent()
=
High Temp Charging:Current Med
HV
—
ChargingCurrent()
=
High Temp Charging:Current High
4.5 Charging Voltage
The
ChargingVoltage()
changes depending on the detected temperature per the charge algorithm.
Note
Table priority is top to bottom.
Temp Range
Condition
Action
Any
OperationStatus()[XCHG]
= 1
ChargingVoltage()
= 0
UT or OT
—
ChargingVoltage()
= 0
LT
—
ChargingVoltage()
=
Low Temp Charging:Voltage
× (
DA Configuration[Cell
Count]
+ 1)
STL or STH
—
ChargingVoltage()
=
Standard Temp Charging:Voltage
× (
DA
Configuration[Cell Count]
+ 1)
RT
—
ChargingVoltage()
=
Rec Temp Charging:Voltage
× (
DA Configuration[Cell
Count]
+ 1)
HT
—
ChargingVoltage()
=
High Temp Charging:Voltage
× (
DA Configuration[Cell
Count]
+ 1)
4.6 Valid Charge Termination
The charge termination condition must be met to enable valid charge termination. The device has the following
actions at charge termination, based on the flags settings:
Advanced Charge Algorithm
SLUUCO0 – APRIL 2022
BQ28Z610-R2
25
Copyright © 2022 Texas Instruments Incorporated