DISCHARGE Mode
RELAX Mode
Current
<
(–
)
Dsg Current Threshold
Current
> (–
)
for
Quit Current
Dsg Relax T
ime
period
CHARGE Mode
Current
>
Chg Current Threshold
Current
<
Quit Current
for
Chg Relax T
ime
period
OCV update
Qmax
update
[DSG
]
Cell Impedance
update
[DSG
]
Current
>
Chg Current Threshold
Current
<
(–
)
Dsg Current Threshold
Figure 6-1. Gas Gauge Operating Modes
CHARGE mode is exited and RELAX mode is entered when
Current
goes below
Quit Current
for a period
of
Chg Relax Time
. DISCHARGE mode is entered when
Current
goes below
(–)Dsg Current Threshold
.