Status
Condition
Action
Trip
PTO timer >
PTO:Delay
Stop PTO timer
SafetyStatus()[PTO]
=1
OperationStatus()[XCHG]
= 1
Reset
SafetyStatus()[PTO]
= 1 AND
(Discharge by an amount of
PTO:Reset
)
Stop and reset PTO timer
SafetyAlert()[PTOS]
= 0
SafetyStatus()[PTO]
= 0
BatteryStatus()[TCA]
= 0
OperationStatus()[XCHG]
= 0
2.13 Fast Charge Timeout Protection
The device can measure the charge time, and stop charging if it exceeds the adjustable period.
Status
Condition
Action
Enable
Current()
>
CTO:Charge Threshold AND
(
ChargingStatus()[LV]
= 1 OR
ChargingStatus()[MV]
= 1 OR
ChargingStatus()[HV]
= 1)
Start CTO timer
SafetyAlert()[CTOS]
= 0
Suspend or Recovery
Current()
<
CTO:Suspend Threshold
Stop CTO timer
SafetyAlert()[CTOS]
= 1
Trip
CTO time >
CTO:Delay
Stop CTO timer
SafetyStatus()[CTO]
= 1
BatteryStatus()[TCA]
= 1
OperationStatus()[XCHG]
=1
Reset
SafetyStatus()[CTO]
= 1 AND
(Discharge by an amount of
CTO:Reset
)
Stop and reset CTO timer
SafetyAlert()[CTOS]
= 0
SafetyStatus()[CTO]
= 0
BatteryStatus()[TCA]
= 0
OperationStatus()[XCHG]
= 0
Protections
18
BQ28Z610-R2
Copyright © 2022 Texas Instruments Incorporated