Class
Subclass
Name
Type
Min
Max
Default
Unit
Description
Protections
COV
Recovery High
Temp
I2
0
32767
3900
mV
Cell overvoltage high temperature
range recovery threshold
Protections
COV
Recovery Rec
Temp
I2
0
32767
3900
mV
Cell overvoltage recommended
temperature range recovery threshold
13.10.3 OCC—Overcurrent In Charge
Class
Subclass
Name
Type
Min
Max
Default
Unit
Description
Protections
OCC
Threshold
I2
–32768
32767
6000
mA
Overcurrent in Charge trip
threshold
Protections
OCC
Delay
U1
0
255
0
s
Overcurrent in Charge trip
delay
Protections
OCC
Recovery
Threshold
I2
–32768
32767
200
mA
Overcurrent in Charge
recovery threshold
Protections
OCC
Recovery Delay
U1
0
255
5
s
Overcurrent in Charge
recovery delay
13.10.4 OCD—Overcurrent In Discharge
Class
Subclass
Name
Type
Min
Max
Default
Unit
Description
Protections
OCD
Threshold
I2
–32768
32767
–6000
mA
Overcurrent in Discharge trip threshold
Protections
OCD
Delay
U1
0
255
6
s
Overcurrent in Discharge trip delay
Protections
OCD
Recovery
I2
–32768
32767
50
mA
Overcurrent in Discharge recovery threshold
Protections
OCD
Recovery Delay
U1
0
255
5
s
Overcurrent in Discharge recovery delay
13.10.5 AOLD—AFE Over Load In Discharge
Class
Subclass
Name
Type
Min
Max
Default
Unit
Description
Protections
AOLD
Threshold
H1
0x00
0xFF
0xF4
hex
AOLD: Threshold
Setting, Bits 7–4: OLDD: AOLD delay time
Setting, Bits 3–0: OLDV: AOLD threshold
Protections
AOLD
Recovery
U1
0
255
5
s
Overload recovery time
13.10.6 ASCC—AFE Short Circuit in Charge
Class
Subclass
Name
Type
Min
Max
Default
Unit
Description
Protections
ASCC
Threshold
H1
0x00
0xFF
0x77
hex
ASCC: Threshold
Setting, Bits 7–4: SCCD: ASCC delay time
Setting, Bit 3: Reserved
Setting, Bits 2–0: OLDV: AOLD threshold Setting
Protections
ASCC
Recovery
U1
0
255
5
s
Overload recovery time
13.10.7 ASCD—AFE Short Circuit in Discharge
Class
Subclass
Name
Type
Min
Max
Default
Unit
Description
Protections
ASCD
Threshold 1
H1
0x00
0xFF
0x77
hex
ASCD: Threshold 1
Setting, Bits 7–4: SCD1D: SCD1 delay time
Setting, Bit 3: Reserved
Setting, Bits 2–0: SCD1V: SCD1 threshold setting
Protections
ASCD
Threshold 2
H1
0x00
0xFF
0xE7
hex
ASCD: Threshold 2
Setting, Bits 7–4: SCD2D: SCD2 delay time
Setting, Bit 3: Reserved
Setting, Bits 2–0: SCD2V: SCD2 threshold setting
Protections
ASCD
Recovery
U1
0
255
5
s
Overload recovery time
13.10.8 OTC—Overtemperature in Charge
Class
Subclass
Name
Type
Min
Max
Default
Unit
Description
Protections
OTC
Threshold
I2
–400
1500
550
0.1°C
Overtemperature in Charge trip threshold
Protections
OTC
Delay
U1
0
255
2
s
Overtemperature in Charge Cell trip delay
Data Flash Values
SLUUCO0 – APRIL 2022
BQ28Z610-R2
111