Status
Condition
Action
Normal
DSG FET off AND
Current()
> D
FET:OFF Threshold
PFAlert()[DFETF]
= 0
Alert
DSG FET off AND
Current()
≤
DFET:OFF Threshold
PFAlert()[DFETF]
= 1
Trip
DSG FET off AND
Current()
continuously ≤
DFET:OFF Threshold
for
DFET:OFF Delay
duration
PFAlert()[DFETF]
= 0
PFStatus()[DFETF]
= 1
Table 3-2. DFET Data Flash Configuration
Class
Subclass
Name
Type
Min Value
Max Value
Default
Value
Unit
Permanent Fail
DFET
OFF Threshold
I2
–500
0
–5
mA
Permanent Fail
DFET
Delay
U1
0
255
5
s
3.6.2 Feature Enable/Disable
The feature is enabled when
DFETF
is set in
Enable PF C
.
3.7 Instruction Flash (IF) Checksum Permanent Fail
The device can permanently disable the battery if it detects a difference between the stored IF checksum and
the calculated IF checksum only following a device reset.
Status
Condition
Action
Normal
Stored and calculated IF checksum match
—
Trip
Stored and calculated IF checksum after reset does not match.
PFStatus()[IFC]
= 1
BatteryStatus()[TCA]
= 1
BatteryStatus()[TDA]
= 1
3.8 Data Flash (DF) Permanent Fail
The device can permanently disable the battery in case a data flash write fails.
Note
A DF write failure causes the gauge to disable further DF writes.
Status
Condition
Action
Normal
Data flash write ok
—
Trip
Data flash write not successful
PFStatus()[DFW]
= 1
BatteryStatus()[TCA]
= 1
BatteryStatus()[TDA]
= 1
Permanent Fail
SLUUCO0 – APRIL 2022
BQ28Z610-R2
21