Class
Subclass
Name
Type
Min
Max
Default
Unit
Description
Gas Gauging
IT Cfg
Design
Resistance
Averaged cell resistance at
Reference Grid
point.
Automatically updated when Update Status is set
to 0x6 by the gauge. To automatically update
again, set Update Status to 0x4 or manually set
when Update Status is set to 0x6.
Gas Gauging
IT Cfg
User-Rate-mA
I2
–32768
32768
0
mA
Discharge rate used for capacity calculation
selected by Load Select
Gas Gauging
IT Cfg
User-Rate-mW
I2
–32768
32768
0
10 mW
Discharge rate used for capacity calculation
selected by Load Select
Gas Gauging
IT Cfg
Reserve Cap-
mAh
I2
0
9000
0
mAh
Capacity is reserved available when the gauging
algorithm reports 0%
RelativeStateOfCharge()
.
Gas Gauging
IT Cfg
Reserve Cap-
cWh
I2
0
32000
0
cWh
Capacity reserved is available when the gauging
algorithm reports 0%
RelativeStateOfCharge()
.
13.6.12 Condition Flag
Class
Subclass
Name
Type
Min
Max
Default
Unit
Description
Gas
Gauging
Condition
Flag
Max Error Limit
U1
1
100
100
%
Max Error Limit Percentage
13.6.13 SOH
Class
Subclass
Name
Type
Min
Max
Default
Unit
Description
Gas Gauging
SOH
SOH Load Rate
U1
1
255
50
0.1 Hr
rate
Current rate used in SOH simulation
13.6.14 Max Error
Class
Subclass
Name
Type
Min
Max
Default
Unit
Description
Gas
Gauging
Max Error
Time Cycle
Equivalent
U1
1
255
12
2h
After valid QMax update, each passed time period of
Time Cycle Equivalent will increment of
MaxError()
by
Cycle Delta. Time Cycle Equivalent increments Max
Error by 0.05% for every Time Cycle Equivalent time
period following the last QMax update.
Gas
Gauging
Max Error
Cycle Delta
U1
0
255
5
0.01% Each increment of
CycleCount()
after valid QMax
update will increment of
MaxError()
by Cycle Delta.
Setting this parameter to 0 disables the MaxError
increment by time or cycle increment.
13.7 System Data
13.7.1 Manufacturer Data
Class
Subclass
Name
Type
Min
Max
Unit
Description
System Data
Manufacturer
Data
Manufacturer Info A
Length
U1
0
32
—
ManufacturerInfo()
length
System Data
Manufacturer
Data
Manufacturer Info
Block A01-A32
U1
ManufacturerInfo()
value
13.7.2 Integrity
Class
Subclass
Name
Type
Min
Max
Default
Unit
Description
System Data
Integrity
Static DF
Signature
H2
0
7FFF
0
hex
Status data flash signature. Use MAC
StaticDFSignature()
(with MSB set to 0) to initialize
this value.
System Data
Integrity
Static Chem DF
Signature
H2
0
7FFF
6C98
hex
Status Chemistry data signature. Use MAC
StaticChemDFSignature()
(with MSB set to 0) to
initialize this value.
System Data
Integrity
All DF Signature
H2
0
7FFF
0
hex
Status data flash signature. Use MAC
AllDFSignature()
(with MSB set to 0) to initialize this
value.
Data Flash Values
SLUUCO0 – APRIL 2022
BQ28Z610-R2
109