4.1 Introduction
The device can change the values of
ChargingVoltage()
and
ChargingCurrent()
based on
Temperature()
and
Cell Voltage1..2()
. Its flexible charging algorithm is JEITA-compatible and can also meet other specific cell
manufacturer charge requirements. The
ChargingStatus()
register shows the state of the charging algorithm.
C
e
ll
V
o
lt
a
g
e
CVH
CVM
CVL
Temperature
T1
T2
T5
T6
T3
T4
CHG
SUSP
CHG
INHIBIT
CHG NORMAL
CHG
INHIBIT
CHG
SUSP
PCHG
LT CCH
STL CCH
STH CCH
RT CCH
HT CCH
LT CCM
STL CCM
STH CCM
RT CCM
HT CCM
LT CCL
STL CCL
STH CCL
RT CCL
HT CCL
4.2 Charge Temperature Ranges
The measured temperature is segmented into several temperature ranges. The charging algorithm adjusts
ChargingCurrent()
and
ChargingVoltage()
according to the temperature range. The temperature ranges set in
data flash should adhere to the following format:
T1
≤
T2
≤
T5
≤
T6
≤
T3
≤
T4
Chapter 4
Advanced Charge Algorithm
Advanced Charge Algorithm
SLUUCO0 – APRIL 2022
BQ28Z610-R2
23