Flag
Clear Criteria
Clear Condition
Enable
[FC]
Cell Voltage
Max cell voltage1..2 ≤
FC: Clear Voltage
Threshold
SOCFlagConfigB[FCClearV]
= 1
RSOC (enable by default)
RelativeStateOfCharge()
≤
FC: Clear %
RSOC Threshold
SOCFlagConfigB[FCClearRSOC]
= 1
The tables below summarize the various options to set and clear the
[TD]
and
[FD]
flags in both
BatteryStatus()
and
GaugingStatus()
.
Flag
Set Criteria
Set Condition
Enable
[TD]
Cell Voltage
Max cell voltage1..2 ≤
TD: Set Voltage
Threshold
SOCFlagConfigA[TDSetV]
= 1
RSOC (enable by default)
RelativeStateOfCharge()
< =
TD: Set %
RSOC Threshold
SOCFlagConfigA[TDSetRSOC]
= 1
[FD]
Cell Voltage
Max cell voltage1..2 ≤
FD: Set Voltage
Threshold
SOCFlagConfigB[FDSetV]
= 1
RSOC (enable by default)
RelativeStateOfCharge()
≤
FD: Set % RSOC
Threshold
SOCFlagConfigB[FDSetRSOC]
= 1
Flag
Clear Criteria
Clear Condition
Enable
[TD]
Cell Voltage
Max cell voltage1..2 ≥
TD: Clear Voltage
Threshold
SOCFlagConfigA[TDClearV]
= 1
RSOC (enable by default)
RelativeStateOfCharge()
≥
TD: Clear % RSOC
Threshold
SOCFlagConfigA[TDClearRSOC]
= 1
[FD]
Cell Voltage
Max cell voltage1..2 ≥
FD: Clear Voltage
Threshold
SOCFlagConfigB[FDClearV
] = 1
RSOC (enable by default)
RelativeStateOfCharge()
≥
FD: Clear % RSOC
Threshold
SOCFlagConfigB[FDClearRSOC]
= 1
4.8 Terminate Charge and Discharge Alarms
When the protections are triggered, the
BatteryStatus()[TCA][TDA][FD][OCA][OTA]
flags are set according to
gauging status and safety protections. The following is a summary of the set conditions and their various alarm
flags:
[TCA]
= 1
•
SafetyAlert()[OCC], [COV], [OTC]
= 1 OR
•
GaugingStatus()[TC]
= 1 AND in CHARGE mode
[OCA]
= 1 if
•
SafetyStatus()[OC]
= 1 AND in CHARGE mode
[TDA]
= 1
•
SafetyAlert()[OCD], [COV], [OTC]
= 1 OR
•
GaugingStatus()[TD]
= 1 AND in DISCHARGE mode
[FD]
= 1 if
•
GaugingStatus()[FD]
= 1
[OTA]
= 1 if
•
SafetyStatus()[OTC], [OTD]
= 1
4.9 Precharge
The device enters PRECHARGE mode if any cell voltage goes below
Charging Voltage Low
. The external
CHG FET can be used in PRECHARGE mode. Setting the
Pre-Charging: Current
= 0 mA disables the
Advanced Charge Algorithm
SLUUCO0 – APRIL 2022
BQ28Z610-R2
27
Copyright © 2022 Texas Instruments Incorporated