TPMC533 User Manual Issue 1.0.1
Page 61 of 107
Bit
Symbol
Description
Access
Reset
Value
23:20
-
Reserved
-
-
19
DAC4_DONE_ENA
Enable IRQ after DAC4 Conversion is done
Refer to the Enable IRQ after DAC1 Conversion is done
bit for description.
For TPMC533-20R: Reserved
R/W
0
18
DAC3_DONE_ENA
Enable IRQ after DAC3 Conversion is done
Refer to the Enable IRQ after DAC1 Conversion is done
bit for description.
For TPMC533-20R: Reserved
R/W
0
17
DAC2_DONE_ENA
Enable IRQ after DAC2 Conversion is done
Refer to the Enable IRQ after DAC1 Conversion is done
bit for description.
For TPMC533-20R: Reserved
R/W
0
16
DAC1_DONE_ENA
Enable IRQ after DAC1 Conversion is done
0: disabled
1: enabled
If enabled, in Manual Mode an interrupt will be
generated after DAC1 has settled (DAC1_SETTLE
changes from '1' to '0' in Global DAC Status Register).
For TPMC533-20R: Reserved
R/W
0