Störungen,Ur-
sachen, Behebung
Faults, causes,
remedies
Storingen, oorzaa-
ken en remedie
Fel, Orsak,
Åtgärd
Défaillances, cau-
ses et dépannage
Disturbi: cause e
rimedi
14
Fault:
Cause:
Correction:
- drive motor not func-
tioning
-tank empty
-fill
(observe type
of fuel!)
- defective fuse for drive
motor
- exchange
- starter battery
discharged
- charge starter
battery
- drive chain not func-
tioning
Cable remote control
not connected
- Connect
- Machine not in
transport position
- place in transport
position
- key operated switch
for operating console in
wrong position
- select correct
position
- emergency stop button
activated
- deactivate
- interrupted power
supply
- establish power
supply
- no platform function
possible from cage
- operating console no
switched on
- turn key operated
switch to “I”
-
Emergency stop
button activated in work
cage and/or at the
bottom control
- deactivate
- no supply voltage
(possibly too weak)
-FI – circuit breaker
tripped
- check
- switch on