Fermzilla Leak Fix Instruction 

Manual  

(for Unitank and All Rounder models) 

 

 

 

 

 

 

 

 

 

Summary of Contents for Fermzilla Unitank Series

Page 1: ...Page 1 of 6 www KegLand com au Last Updated 24 03 2020 4 30 PM Fermzilla Leak Fix Instruction Manual for Unitank and All Rounder models ...

Page 2: ... lid of the Fermzilla making sure to cover the entirety of the lid including underneath the lid collar the entirety of the lid and around the PET caps carbonation caps Look for the formation of bubbles indicating a leak 2 Invert the Fermzilla and submerge the lid in a bucket of water sink bath or pool Look for any bubbles forming in the water indicating a leak If you identify a leak in the lid the...

Page 3: ...teel handles are not too tight Loosen these handles or remove and then perform another leak test The handles should only be hand tight as too tight can result in distortion of the neck of the Fermzilla If you are still experiencing issues please send through a video to the email beer kegland com au showing where the leak is occurring leak test and photos of the condition of the lid and o ring NOTE...

Page 4: ...king from the base If the carbonation cap is leaking from the base of the carbonation cap then perform the following steps Step 1 If a leak is identified then unscrew the carbonation cap and inspect the o ring inside the carbonation cap If there are any signs of damage including cuts burs or scratches then replace the o ring NOTE If you determine that the o ring is damaged you may need to replace ...

Page 5: ...up of protein or hop matter from inside the the carbonation cap Step 3 Reassemble the carbonation cap and hand tighten onto the lid of the Fermzilla Then perform another leak test Gas bubbles in beer line from carbonation cap If gas bubbles are forming in your beer line then this may be an indication that the inner o ring shown below is damaged This should be replaced with a new o ring If you are ...

Page 6: ...fly valve There should be no thread showing If it still leaks after hand tightening then torque it another of a turn with the oil removal tool Step 4 Perform a leak test Collection vessel overtightened and difficult to remove If you have overtightened the collection vessel and the spigot collar is spinning preventing you from removing the collection vessel then perform the following steps Step 1 A...