6.2.3 Battery Check Set
This command is used to set/reset the battery check period after the battery check has been
started. Upon receipt, the GS node records the new value of the battery check frequency so
that GS node performs the battery voltage check with the new value set.
Command Syntax
AT+BCHK=<Battery check frequency>
Alternate Command
The same command can be used to get the current configured battery check period, the
usage as follows:
AT+BCHK=?
Parameter Description
describes the Battery Check Set parameters.
Synchronous Response
describes the synchronous responses and remarks for Battery Check
Set command.
Table 126 Battery Check Set Parameters
Parameter
Optional/Mandatory
Value
Description
Battery check frequency Mandatory
1-100
The valid range for Battery check
frequency is between 1 and 100.
Table 127 Battery Check Set Synchronous Responses
Responses
Remarks
OK
Success
ERROR:INVALID INPUT
If parameters are not valid.