Understanding Histograms
E-6
E
INTERCEPTOR 147 2 Mbit/s and Data Analyzer
3.
Transition Information Labeled Avl Sec, Storage,
and Power
The Transition Information lines correspond to
the Transition Bars available with Graph
histograms. In List histograms, the transition
information is indicated by a list of numbers
(separated by commas). Each number represents
the condition for the given time period. In the
example shown, the first number indicates the
condition during the first time period (that is, the
first 255 seconds), etc. The numbers represent
the conditions listed below.
Figure E-3
Sample List Histogram Print
4.
Mode Change Information
The numbers on Modechng (Mode Change) line
report the following information regarding mode
changes:
0
No mode change occurred.
1
A mode change occurred.
5
Unable to determine; may occur
immediately after power up.
5.
Information About the Histogram
At the bottom of the List Histogram is a list of
information about the histogram. This
information is the same as is reported with Graph
histograms.
===================================
Start Of Acquisition:
Start Of Print (DD/HH:MM):
Duration Of Print (DD/HH:MM):
Seconds Per Bar (Seconds):
Seconds Per Bar (DD/HH:MM:SS):
Last Second Of Data (DD/HH:MM:SS):
23:49:42 30-Oct-1994
00/00:00
00/04:15
255
00/00:04:15
00/04:49:46
HISTOGRAM PRINT 13:55:36 1-Apr-1994
Bit Errs
0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,
0,6643,2699,0,0,473,1902,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,
0,0.0.0
*Storage
1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,3,
2,1,1,1,1,1,3,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,4,1,4,1
*Power
1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,5,
5,0,2,5,5,5,5,5,5,5,5,5,5,5,5,5,5,5,5,5,5,5,5,1,5,1
*Modechng
0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,5,
5,0,0,1,0,0,5,5,5,5,5,5,5,5,5,5,5,5,5,5,5,5,5,5,5,5,5,0,5,1
1
5
4
3
2
Summary of Contents for interceptor 147
Page 2: ...Specifications terms and conditions are subject to change without notice ...
Page 42: ...Instrument Description 2 24 2 INTERCEPTOR 147 2 Mbit s and Data Analyzer ...
Page 100: ...3 Setup Categories 3 58 INTERCEPTOR 147 2 Mbit s and Data Analyzer ...
Page 116: ...Test Results 4 16 4 INTERCEPTOR 147 2 Mbit s and Data Analyzer ...
Page 208: ...Applications 7 28 7 INTERCEPTOR 147 2 Mbit s and Data Analyzer ...
Page 218: ...Specifications 8 10 8 INTERCEPTOR 147 2 Mbit s and Data Analyzer ...
Page 226: ...9 9 8 INTERCEPTOR 147 2 Mbit s and Data Analyzer Maintenance and Service ...
Page 228: ...Printer Remote Control Interface A 2 A INTERCEPTOR 147 2 Mbit s and Data Analyzer ...
Page 280: ...Index INDEX 10 INTERCEPTOR 147A 2Mbit s Analyzer ...