Specifications
1- 28
WVR6100, WVR7000, and WVR7100 Specifications and Performance Verification
Table 1- 35: Audio bar displays (Option DS) (Cont.)
Characteristic
Reference information
Performance requirement
Adjustable Test Level (dBFS)
Range 0 to –30.
Test level is the level relative to
digital full scale that you choose as
the test or “line up” level for your
system. The meter bars change to
yellow between the Test and Peak
Program levels.
Set 0 dB Mark
Select dBFS, Peak Program level, or Test
level.
Use this item to number the meter
scale relative to Digital Full scale or
to one of the two user-adjustable
levels. When the zero mark is set to
either Peak Program or Test level,
the scale units are dBr, relative to
the 0 dB level; units above the
selected 0 dB mark are positive,
while units below it are negative.
Table 1- 36: Audio bar and aux displays (Option DS)
Characteristic
Performance requirement
Reference information
Phase Display AGC
AGC (automatic gain control) may be
configured on or off.
AGC time constant: 0.5 sec to
expand display after a 0 to –40 level
transition, 0.05 sec to reduce gain
after a –40 to 0 dB level transition.
Phase Display Manual Scaling
When AGC is off, level at perimeter of display
follows Program Level on Bar display.
Phase Display Source Selection
Provides independent selection of any two
channels of the selected audio input.
Surround Display
Provides a dynamic graphic display of
multi-channel surround sound with integrated
indicators for levels, correlations and dominant
location. Provided with permission of RTW
RADIO-TECHNISCHE WERKSTAETTEN
GmbH & Co.).
Surround Dominance Indicator
Selectable on or off.
Surround Sound Filter
Selectable Linear (RMS) or A--Weighted.
A--Weighting filter conforms to IEC651 Type 0.