![Tektronix WVR6100 Series Instructions Manual Download Page 36](http://html1.mh-extra.com/html/tektronix/wvr6100-series/wvr6100-series_instructions-manual_1078279036.webp)
Specifications
1- 24
WVR6100, WVR7000, and WVR7100 Specifications and Performance Verification
Table 1- 33: Jitter Display characteristics (Option PHY) (Cont.)
Characteristic
Reference information
Performance requirement
Digital Readout
Type
Displays peak-to-peak value of jitter
over the measurement interval, as
defined by the High Pass Filter
setting.
Accuracy, typical
Error for jitter frequencies between
HPF setting and 5x HPF setting due
to loop peaking, maximum of 1.5 dB.
HD at 10 Hz HPF
Within 0.3 UI + 10% of reading for
jitter frequencies from 5x bandwidth
selection to 4 MHz.
HD at 100 Hz to 100 kHz HPF
SD at All HPF Settings
Within 0.05 UI + 10% of reading for
jitter frequencies from 5x bandwidth
selection to 4 MHz.
Resolution
0.01 UI
Jitter Waveform
Amplitude Error, typical
Error for jitter frequencies between
HPF setting and 5x HPF setting due
to loop peaking, maximum of 1.5 dB.
HD at 10 Hz HPF
Within 0.4 UI + 10% of reading for
jitter frequencies from 5x bandwidth
selection to 4 MHz.
HD at 100 Hz to 100 kHz HPF
SD at All HPF Settings
Within 0.1 UI + 10% of reading for
jitter frequencies from 5x bandwidth
selection to 4 MHz.
Scale
Horizontal
1 Line, 2 Line, 1 Field, and 2 Field
modes.
Vertical
1 UI/div, 0.2 UI/div, and variable
0.1 UI/div to 2.5 UI/div.
Jitter Measurement Time
0.5 s
Approximately 10,000,000 indepen-
dent samples.