![Tektronix WVR6100 Series Instructions Manual Download Page 38](http://html1.mh-extra.com/html/tektronix/wvr6100-series/wvr6100-series_instructions-manual_1078279038.webp)
Specifications
1- 26
WVR6100, WVR7000, and WVR7100 Specifications and Performance Verification
Option DS (Digital Audio) is available for the WVR6100, WVR7000, and
WVR7100. Tables 1--35 through 1--37 list the the characteristics specific to
Option DS.
Table 1- 35: Audio bar displays (Option DS)
Characteristic
Performance requirement
Reference information
Modes
The user may configure the response
dynamics (ballistics), reference levels, peak
hold, offset, and scale of the meters to suit the
monitoring needs of the particular installation
or situation. Each pair has a phase correlation
meter.
Pair Mode
Any 4 channel pairs with phase correlation
meters.
Surround Mode
Left, Right, Center, Low-frequency-effects,
Left-surround, Right-surround meters, and an
extra channel pair. Phase correlation meters
between the two left- right-pairs and the extra
pair.
Audio Sources
Selected from AES A inputs, AES B inputs
embedded audio.
Level Meter Resolution
0.056 dB steps at 30 dB scale, for from full
scale to –20 dB FS.
0.20 dB Steps at 0 to –70 dB scale, for signals
above –20 dB FS, Tiled display.
Correlation Meter Speed
User selectable 1 to 20. Factory default set
to 8.
Speed 1 averages over 0.0167 s
Speed 2 averages over 0.0333 s
Speed 3 averages over 0.0667 s
Speed 4 averages over 0.133 s
Speed 5 averages over 0.267 s
Speed 6 averages over 0.533 s
Speed 7 averages over 1.0 s
Speed 8 averages over 1.5 s
Speed 9 averages over 2.0 s
Speed 10 averages over 2.5 s
Speed 11 averages over 3.0 s
Speed 12 averages over 3.5 s
Speed 13 averages over 4.0 s
Speed 14 averages over 4.5 s
Speed 15 averages over 5.0 s
Speed 16 averages over 5.5 s
Speed 17 averages over 6.0 s
Speed 18 averages over 6.5 s
Speed 19 averages over 7.0 s
Speed 20 averages over 7.5 s
Metering Ballistics
Selectable from true peak, PPM type 1, PPM
Type 2, and Extended VU.
Audio Option DS