Performance Verification
4–14
WFM 601 - Service Manual
i.
Horizontally and vertically position the display over the center 8
divisions of the graticule 0 line.
j.
CHECK – for 8 divisions of deflection
0.4 minor divisions.
12. Check Vector Mode Bandwidth Matching
REQUIREMENT – Horizontal-to-Vertical Bandwidth Matching:
2
°
loop
opening at 500 kHz or 2 MHz.
a. Select the multiburst signal from the serial digital component Generator.
(It is located under the multipulse signal graphic; it toggles with the
multipulse signal when the button is pushed.)
b. Turn on generator R–Y.
c.
CHECK – that there is less than a trace width of loop opening.
13. Check Vector Registration
REQUIREMENT –
0.25 box with the X1 color black dot centered in box.
a. Center the color black dot, with the HORIZ and VERT POS controls in
the center box.
b. Enter the GAIN menu and select X5.
c.
CHECK – that the color black dot is within
1
/
4
inch of the center of its
box.
d. Change the vertical gain (GAIN menu) to X10.
e.
CHECK – that the color black dot is within
1
/
2
inch of the center of its
box.
14. Check Lightning Mode
REQUIREMENT – Y displayed on vertical axis, B–Y displayed horizontally
on top half of the display, R–Y displayed horizonatally on the bottom half of the
display. Vertical Gain Accuracy:
2%.
a. Select the color bar signal from the serial digital component generator.
b. Turn on the LIGHTNING VIDEO DISPLAY.
c.
Turn off the generator B–Y and R–Y channels.
d. CHECK – that the signal vertical amplitude is 10 divisions
1 minor
division (–.3 to .7).
e.
Turn on generator B–Y and R–Y channels.
Summary of Contents for WFM601
Page 4: ...The WFM601 Serial Digital Component Monitor...
Page 10: ...Contents iv WFM 601 Service Manual Revised Nov 1994...
Page 14: ...Contents viii WFM 601 Service Manual Revised Nov 1994...
Page 19: ......
Page 32: ......
Page 50: ...Installation 2 18 WFM 601 Service Manual...
Page 57: ......
Page 87: ...Theory of Operation 3 30 WFM 601 Service Manual...
Page 88: ......
Page 110: ...Performance Verification 4 22 WFM 601 Service Manual...
Page 111: ......
Page 132: ......
Page 168: ...Maintenance 6 36 WFM 601 Service Manual...
Page 169: ......
Page 175: ...Options 7 6 WFM 601 Service Manual...
Page 176: ......
Page 177: ......
Page 226: ......
Page 233: ...WFM 601 SERIAL COMPONENT MONITOR BNC INPUT BOARDS 1...
Page 237: ...ECL TO TTL CONVERTER LINE BUFFER RAM WFM 601 SERIAL COMPONENT MONITOR COPROCESSOR 3...
Page 245: ...Y FILTER Pb FILTER Pr FILTER WFM 601 SERIAL COMPONENT MONITOR Y Pb Pr RECONSTRUCTION FILTERS 7...
Page 247: ...WFM 601 SERIAL COMPONENT MONITOR TRANSCODERS PIX MONITOR OUTPUTS 8...
Page 249: ...0 0 0 0 WFM 601 SERIAL COMPONENT MONITOR LIGHTNING VECTOR BOWTIE SWITCHING 9...
Page 251: ...WFM 601 SERIAL COMPONENT MONITOR CONTROL DACULATOR 10...
Page 259: ...ROM MICROPROCESSOR NOVRAM RAM FLASH EPROM BUFFERS RESET ABORT WFM 601 SERIAL COMPONENT MONITOR...
Page 265: ......
Page 271: ...WFM 601 SERIAL COMPONENT MONITOR FRONT PANEL 20...
Page 282: ...WFM 601 FIG 1 EXPLODED VIEW A1 A2 A3 A4 A4A1 A5 A6 A7 A8...
Page 290: ...Glossary Glossary 8 WFM601 Serial Component Monitor...