Performance Verification
WFM 601 - Service Manual
4–7
Verification Procedure
1. Preliminary Setup
a. Connect the WFM
601 ac power cord to the variable autotransformer.
Set the mains Power switch for the autotransformer to On. Set the
autotransformer to the local nominal mains voltage (110 V or 220 V).
b. Connect a serial digital output from the digital component television test
signal generator to the WFM
601 SER A input; terminate the remaining
side of the loop-through connector with a 300 MHz, 75
end-line
termination.
c.
Connect a second serial digital output from the digital component
television test signal generator to the SER B input; terminate the
remaining side of the loop-through connector with a 300 MHz, 75
end-line termination.
d. Connect the digital component television test signal generator black
burst signal to the WFM
601 EXT REF connector. Connect a 75
end-line termination to the remaining side of the EXT REF loop-through
connector.
e.
Turn the WFM 601 POWER ON.
f.
Enter the CRT menu and adjust the controls for best viewing of the
display. Exit the CRT menu.
g. Set the WFM 601 front-panel controls and menu selections to the factory
settings by entering the PRESET menu and selecting FACTORY.
2. Check Power Supply Operation
REQUIREMENT – Stable operation over an ac input range of 90 – 250 V.
a. Vary the autotransformer from low-line to high-line voltage (90 – 132 V
for 110 V, or 180 – 250 V for 220 V operation).
b. CHECK – for stable instrument operation over the prescribed voltage
range, 90 – 132 V for 110 V, or 180 – 250 V for 220 V.
c.
Set the autotransformer to the nominal mains voltage.
3. Check Trace Rotation Range and Graticule Illumination
REQUIREMENT – Rotation of
+ & – 1
°
from the horizontal.
a. Enter the CRT menu and select TRACE.
b. Position the trace to the graticule baseline.
Summary of Contents for WFM601
Page 4: ...The WFM601 Serial Digital Component Monitor...
Page 10: ...Contents iv WFM 601 Service Manual Revised Nov 1994...
Page 14: ...Contents viii WFM 601 Service Manual Revised Nov 1994...
Page 19: ......
Page 32: ......
Page 50: ...Installation 2 18 WFM 601 Service Manual...
Page 57: ......
Page 87: ...Theory of Operation 3 30 WFM 601 Service Manual...
Page 88: ......
Page 110: ...Performance Verification 4 22 WFM 601 Service Manual...
Page 111: ......
Page 132: ......
Page 168: ...Maintenance 6 36 WFM 601 Service Manual...
Page 169: ......
Page 175: ...Options 7 6 WFM 601 Service Manual...
Page 176: ......
Page 177: ......
Page 226: ......
Page 233: ...WFM 601 SERIAL COMPONENT MONITOR BNC INPUT BOARDS 1...
Page 237: ...ECL TO TTL CONVERTER LINE BUFFER RAM WFM 601 SERIAL COMPONENT MONITOR COPROCESSOR 3...
Page 245: ...Y FILTER Pb FILTER Pr FILTER WFM 601 SERIAL COMPONENT MONITOR Y Pb Pr RECONSTRUCTION FILTERS 7...
Page 247: ...WFM 601 SERIAL COMPONENT MONITOR TRANSCODERS PIX MONITOR OUTPUTS 8...
Page 249: ...0 0 0 0 WFM 601 SERIAL COMPONENT MONITOR LIGHTNING VECTOR BOWTIE SWITCHING 9...
Page 251: ...WFM 601 SERIAL COMPONENT MONITOR CONTROL DACULATOR 10...
Page 259: ...ROM MICROPROCESSOR NOVRAM RAM FLASH EPROM BUFFERS RESET ABORT WFM 601 SERIAL COMPONENT MONITOR...
Page 265: ......
Page 271: ...WFM 601 SERIAL COMPONENT MONITOR FRONT PANEL 20...
Page 282: ...WFM 601 FIG 1 EXPLODED VIEW A1 A2 A3 A4 A4A1 A5 A6 A7 A8...
Page 290: ...Glossary Glossary 8 WFM601 Serial Component Monitor...