Performance Verification
4–8
WFM 601 - Service Manual
c.
CHECK – that the TRACE ROTATE control moves the trace
w
+ & –
1
°
from the graticule baseline.
d. Adjust the TRACE ROTATE control for a level trace across the graticule
baseline.
e.
From the CRT menu select DISPLAY.
f.
CHECK – that the SCALE control changes the graticule illumination
from completely extinguished to fully illuminated.
g. Adjust the SCALE control for the desired graticule illumination.
h. Exit the CRT menu.
NOTE
. Intensity, readout intensity, and focus are also controlled from the CRT
menu. If any of them needs adjusting during the performance of this procedure,
select the CRT menu and adjust as necessary. The levels set will remain after
the CLEAR MENU or CRT menu button is pushed.
4. Check Horizontal Mag Registration and Position Range
REQUIREMENT – Any portion of the synchronized sweep can be positioned
onscreen in all sweep modes.
a. Horizontally center the display, and then turn on the MAG SWEEP.
b. CHECK – that the start of the trace is displayed.
c.
CHECK – by adjusting the HORIZ POS control, that both ends of the
display can be positioned past the center of the CRT.
d. Turn Off the MAG SWEEP.
5. Check Calibrator Timing Frequency
REQUIREMENT – Frequency: 100 kHz
"
0.1%.
a. Set the frequency counter Timing to 1
m
s.
b. Connect a X1 probe from the frequency counter to the ribbon cable side
of A3R274 (Main board).
c.
Connect the probe ground to the metal shield adjacent to A3L5.
d. Adjust the frequency counter controls for a stable readout.
e.
CHECK – that the counter reading is 100 kHz
"
0.1 kHz.
Summary of Contents for WFM601
Page 4: ...The WFM601 Serial Digital Component Monitor...
Page 10: ...Contents iv WFM 601 Service Manual Revised Nov 1994...
Page 14: ...Contents viii WFM 601 Service Manual Revised Nov 1994...
Page 19: ......
Page 32: ......
Page 50: ...Installation 2 18 WFM 601 Service Manual...
Page 57: ......
Page 87: ...Theory of Operation 3 30 WFM 601 Service Manual...
Page 88: ......
Page 110: ...Performance Verification 4 22 WFM 601 Service Manual...
Page 111: ......
Page 132: ......
Page 168: ...Maintenance 6 36 WFM 601 Service Manual...
Page 169: ......
Page 175: ...Options 7 6 WFM 601 Service Manual...
Page 176: ......
Page 177: ......
Page 226: ......
Page 233: ...WFM 601 SERIAL COMPONENT MONITOR BNC INPUT BOARDS 1...
Page 237: ...ECL TO TTL CONVERTER LINE BUFFER RAM WFM 601 SERIAL COMPONENT MONITOR COPROCESSOR 3...
Page 245: ...Y FILTER Pb FILTER Pr FILTER WFM 601 SERIAL COMPONENT MONITOR Y Pb Pr RECONSTRUCTION FILTERS 7...
Page 247: ...WFM 601 SERIAL COMPONENT MONITOR TRANSCODERS PIX MONITOR OUTPUTS 8...
Page 249: ...0 0 0 0 WFM 601 SERIAL COMPONENT MONITOR LIGHTNING VECTOR BOWTIE SWITCHING 9...
Page 251: ...WFM 601 SERIAL COMPONENT MONITOR CONTROL DACULATOR 10...
Page 259: ...ROM MICROPROCESSOR NOVRAM RAM FLASH EPROM BUFFERS RESET ABORT WFM 601 SERIAL COMPONENT MONITOR...
Page 265: ......
Page 271: ...WFM 601 SERIAL COMPONENT MONITOR FRONT PANEL 20...
Page 282: ...WFM 601 FIG 1 EXPLODED VIEW A1 A2 A3 A4 A4A1 A5 A6 A7 A8...
Page 290: ...Glossary Glossary 8 WFM601 Serial Component Monitor...