Removal and Installation Procedures
4-24
AWG7000 Series Service Manual
Power Supply
You need a screwdriver with a T-15 Torx tip (items 1 and 2).
Removal.
To remove the power supply, refer to Figure 4-11 and follow these steps:
1.
Remove the handle unit, snaps, cosmetic covers, front-trim unit, EMI covers,
drive-bay module, and Multi-Input/Output board.
2.
Orient the instrument so that the bottom is on the work surface.
3.
Remove the six screws securing the power supply bracket to the chassis.
4.
Disconnect the cable from J611 on the Power board.
5.
Remove the three screws securing the bracket to the power supply.
6.
Carefully slide the module to loosen it from the Power board.
7.
Lift the power supply up out of the chassis.
8.
Lift the bracket up out of the chassis.
Installation.
To install, reverse this procedure.
RFI Filter
You need a screwdriver with a T-15 Torx tip (items 1 and 2).
Removal.
To remove the power supply, refer to Figure 4-11 and follow these steps:
1.
Remove the handle unit, snaps, cosmetic covers, and EMI covers.
2.
Orient the instrument so that the bottom is on the work surface.
3.
Disconnect the cable from J600 on the Power board.
4.
Remove the two screws securing the ground leads to the chassis.
5.
Remove the two screws securing the RFI filter to the chassis.
6.
Pull the RFI filter away from the chassis.
Installation.
To install, reverse this procedure.
Summary of Contents for AWG7000 Series
Page 4: ......
Page 10: ...List of Tables vi AWG7000 Series Service Manual...
Page 14: ...Service Safety Summary x AWG7000 Series Service Manual...
Page 16: ...Environmental Considerations xii AWG7000 Series Service Manual...
Page 18: ...Preface xiv AWG7000 Series Service Manual...
Page 19: ...Operating Information...
Page 20: ......
Page 23: ...Theory of Operation...
Page 24: ......
Page 31: ...Adjustment Procedures...
Page 32: ......
Page 51: ...Maintenance...
Page 52: ......
Page 58: ...Maintenance 4 6 AWG7000 Series Service Manual...
Page 109: ...Replaceable Parts...
Page 110: ......