Troubleshooting
4-54
AWG7000 Series Service Manual
300000012
The Ipc busy timeout period has expired.
AWG10G
AWG10G: U1000
300000013
MemoryController DLL doesn't lock.
AWG10G
AWG10G: U1000, U400xx
300000014
MemoryController Dynamic Phase Shift - IPC error.
AWG10G
AWG10G: U1000, U400xx
300000015
MemoryController Dynamic Phase Shift - Waveform RAM error.
AWG10G
AWG10G: U1000, U400xx
300000016
MemoryController Dynamic Phase Shift - System Clock error.
AWG10G
AWG10G: U1000, U400xx
300000017
The Diag busy timeout period has expired.
AWG10G
AWG10G: U1000, U400xx
300000018
MemoryController Dynamic Phase Shift - Mux error.
AWG10G
AWG10G: U1000, U400xx
300000019
AWG10G board Calibration checksum data has an error.
AWG10G
300000020
AWG10G board Calibration version unmatched.
AWG10G
300000100
The access of MIO board EEPROM, it failed.
MIO
MIO: U300, U390
300000101
The access of OUTPUT board EEPROM, it failed.
OUT10G
OUT10G: U500, U550
300000102
The relay count is invalid. Board-1
OUT10G
OUT10G: U500, U550
300000103
The relay count is invalid. Board-2
OUT10G
OUT10G: U500, U550
300000104
The access of AWG board EEPROM, it failed.
AWG10G
AWG10G: U1090
300000200
The download (INIT) timeout period has expired.
MIO
MIO: U200,U300
300000201
The download (INIT) timeout period has expired.
MIO
MIO: U200,U300
300000202
The download (DONE) timeout period has expired.
MIO
MIO: U200,U300
300000203
The download timeout period has expired.
MIO
MIO: U200,U300
300000204
The system cannot find the file specified.(PLD140b.Bit)
N/A
300000205
An attempt was made to load a program with an incorrect
format.(PLD131.Bit)
N/A
300000206
The download(AwgController-INIT) timeout period has expired.
MIO, AWG10G
MIO: U300
AWG10G: U1000
MIO-AWG10G Cable
300000207
The download(AwgController-INIT) timeout period has expired.
MIO, AWG10G
MIO: U300
AWG10G: U1000
300000208
The download(DONE) timeout period has expired.
MIO, AWG10G
MIO: U300
AWG10G: U1000
MIO-AWG10G Cable
300000209
The download timeout period has expired.
MIO, AWG10G
MIO: U300
AWG10G: U1000
MIO-AWG10G Cable
300000210
The system cannot find the file specified.(PLD131.Bit)
N/A
300000211
An attempt was made to load a program with an incorrect
format.(PLD131.Bit)
N/A
300000212
The download (AwgController-INIT) timeout period has expired.
MIO, AWG10G
MIO: U300
AWG10G: U1000, U400xx
300000213
The download (AwgController-INIT) timeout period has expired.
MIO, AWG10G
MIO: U300
AWG10G: U1000, U400xx
300000214
The download (AwgController-DONE) timeout period has expired.
MIO, AWG10G
MIO: U300
AWG10G: U1000, U400xx
300000215
The download (AwgController) timeout period has expired.
MIO, AWG10G
MIO: U300
AWG10G: U1000, U400xx
300000216
The system cannot find the file specified.(PLD130b.Bit)
N/A
Table 4-8: Hardware error (cont.)
Error code
Error log message
Possible defect
on board
Note
Summary of Contents for AWG7000 Series
Page 4: ......
Page 10: ...List of Tables vi AWG7000 Series Service Manual...
Page 14: ...Service Safety Summary x AWG7000 Series Service Manual...
Page 16: ...Environmental Considerations xii AWG7000 Series Service Manual...
Page 18: ...Preface xiv AWG7000 Series Service Manual...
Page 19: ...Operating Information...
Page 20: ......
Page 23: ...Theory of Operation...
Page 24: ......
Page 31: ...Adjustment Procedures...
Page 32: ......
Page 51: ...Maintenance...
Page 52: ......
Page 58: ...Maintenance 4 6 AWG7000 Series Service Manual...
Page 109: ...Replaceable Parts...
Page 110: ......