1735 HD High Definition Waveform Monitor
3–1
Specifications
The Performance Requirements listed in the Electrical Specifications apply over
an ambient temperature range of 0
_
C to +50
_
C. The rated accuracies are valid
when the instrument is calibrated at an ambient temperature range of +20
_
C to
+30
_
C, after a warm-up time of 20 minutes.
Test equipment used to verify Performance Requirements must be calibrated and
working within the limits specified in the Recommended Equipment List located
in the Performance Verification section.
Table 3–1: Vertical deflection system
Characteristic
Performance requirements
Supplemental information
Check
step
Frequency Response
1 V Full Scale
FLAT (X1 and X5)
50 kHz to 30 MHz within 2% of
response at 50 kHz.
Specifications apply for 1 V video
input signal (700 mV sinewave), with
VAR gain off.
Verification may be limited by test
equipment capabilities.
16
FILTER
>20 dB of attenuation at 20 MHz.
Response at 15 kHz does not vary
between FLAT and FILTER by more
than 1% when NOISE filter is
selected.
22
Transient Response
1 V Full Scale or X5 Gain
FLAT
Preshoot, Overshoot, and
Ringing.
1% or less.
X1 Specifications apply for 700 mV,
33 ns risetime step, with VAR gain
off.
19, 20
Tilt
21
Field Rate Square Wave or
Vertical Window
1% or less.
Deflection Factor
8
1 V Full Scale
1.0 V within 1% with 1 V input.
FLAT response selected.
X5 Gain
Gain Accuracy
±
5%.
200 mV input signal.
Variable Gain Range
+5 dB, –20 dB.
10
Position Range
1 V signal can be positioned so that
pea k white or sync tip can be placed
at blanking level.
CLAMP on, any gain setting.
10
Summary of Contents for 070-8462-03
Page 5: ......
Page 13: ...Table of Contents viii 1735 HD High Definition Waveform Monitor...
Page 19: ...Preface xiv 1735 HD High Definition Waveform Monitor...
Page 20: ...Getting Started...
Page 21: ......
Page 35: ...Installation 1 14 1735 HD High Definition Waveform Monitor...
Page 36: ...Operating Basics...
Page 37: ......
Page 63: ...Operating Basics 2 26 1735 HD High Definition Waveform Monitor...
Page 64: ...Specifications...
Page 65: ......
Page 75: ...Specifications 3 10 1735 HD High Definition Waveform Monitor...
Page 77: ......
Page 78: ...Theory of Operation...
Page 79: ......
Page 109: ...Theory of Operation 4 30 1735 HD High Definition Waveform Monitor...
Page 110: ...Performance Verification...
Page 111: ......
Page 134: ...Adjustment Procedure...
Page 135: ......
Page 158: ...Maintenance...
Page 159: ......
Page 163: ...Preventive Maintenance 7 4 1735 HD High Definition Waveform Monitor...
Page 179: ...Corrective Maintenance 7 20 1735 HD High Definition Waveform Monitor...
Page 181: ...Repackaging 7 22 1735 HD High Definition Waveform Monitor Figure 7 10 Repackaging...
Page 182: ...Replaceable Electrical Parts...
Page 183: ......
Page 252: ...Diagrams...
Page 253: ......
Page 256: ...Replaceable Mechanical Parts...
Page 257: ......
Page 265: ...Replaceable Mechanical Parts 10 8 1735 HD High Definition Waveform Monitor...
Page 266: ...Appendices...
Page 267: ......
Page 270: ......
Page 271: ......