7–1
Preventive Maintenance
Preventive maintenance consists of cleaning, visual inspection, performance
checks, and (if needed) readjustment. The preventive maintenance schedule
established for the instrument should be based on the amount of use it receives
and the environment in which it is operated. Under average conditions, sched-
uled preventive maintenance should be performed every 2000 hours of operation.
Performance Checks and Readjustments
Instrument performance should be checked after each 2000 hours of operation, or
every 12 months if used intermittently. This will help ensure maximum
performance and assist in locating defects that may not be apparent during
regular operation. The Performance Verification and Adjustment Procedure
sections.
CAUTION.
Do not allow water to get inside any enclosed assembly or component.
Do not clean any plastic materials with benzene, toluene, xylene, acetone, or
similar compounds, because they may damage the plastic.
Cleaning
The instrument should be cleaned often enough to prevent dust and dirt from
accumulating. Dirt acts as a thermal insulator, preventing effective heat
dissipation, and can also provide high-resistance electrical leakage paths between
conductors or components in a humid environment.
Clean the dust from the outside of the instrument with a soft cloth or small
brush. A brush is especially useful for removing dust from around the selector
buttons, knobs, and connectors. Hardened dirt may be removed using a cloth
dampened with a mild detergent and water solution. Abrasive cleaners should not
be used.
Clean the face of the CRT with a soft, lint-free cloth dampened in isopropyl
alcohol or glass cleaner solution. Abrasive cleaners should not be used.
Loosen dust with a soft, dry brush and remove it with low-pressure air (high-ve-
locity air can damage some parts). Hardened dirt or grease can be removed with
a cotton-tipped applicator dampened with a mild detergent and water solution.
Abrasive cleaners should not be used.
Exterior
CRT
Interior
Summary of Contents for 070-8462-03
Page 5: ......
Page 13: ...Table of Contents viii 1735 HD High Definition Waveform Monitor...
Page 19: ...Preface xiv 1735 HD High Definition Waveform Monitor...
Page 20: ...Getting Started...
Page 21: ......
Page 35: ...Installation 1 14 1735 HD High Definition Waveform Monitor...
Page 36: ...Operating Basics...
Page 37: ......
Page 63: ...Operating Basics 2 26 1735 HD High Definition Waveform Monitor...
Page 64: ...Specifications...
Page 65: ......
Page 75: ...Specifications 3 10 1735 HD High Definition Waveform Monitor...
Page 77: ......
Page 78: ...Theory of Operation...
Page 79: ......
Page 109: ...Theory of Operation 4 30 1735 HD High Definition Waveform Monitor...
Page 110: ...Performance Verification...
Page 111: ......
Page 134: ...Adjustment Procedure...
Page 135: ......
Page 158: ...Maintenance...
Page 159: ......
Page 163: ...Preventive Maintenance 7 4 1735 HD High Definition Waveform Monitor...
Page 179: ...Corrective Maintenance 7 20 1735 HD High Definition Waveform Monitor...
Page 181: ...Repackaging 7 22 1735 HD High Definition Waveform Monitor Figure 7 10 Repackaging...
Page 182: ...Replaceable Electrical Parts...
Page 183: ......
Page 252: ...Diagrams...
Page 253: ......
Page 256: ...Replaceable Mechanical Parts...
Page 257: ......
Page 265: ...Replaceable Mechanical Parts 10 8 1735 HD High Definition Waveform Monitor...
Page 266: ...Appendices...
Page 267: ......
Page 270: ......
Page 271: ......