9929758 R01 - 2019 TAYLOR-DUNN G-100 Service Manual
© Copyright TAYLOR-DUNN
3.53
7. Remove valve and check where the Prussian Blue
indicates seat contact on the valve face. The valve
seat should contact the middle of the valve face or
slightly above, and must be the proper width.
NOTICE
When using an interference angle, the seat contact
point on the valve will be very narrow, and is a normal
condition. Look for an even and continuous contact
point all the way around the valve face
e
.
MEASUREMENT
Valve Seat Width:
Intake:
Std.: .0591" (1.50 mm)
Service Limit: .0748" (1.90 mm)
Exhaust:
Std.: .0787” (2.00 mm)
Service Limit: .0945" (2.40 mm)
* If the indicated seat contact is at the top edge of the
valve face and contacts the margin area
w
it is too
high on the valve face. Use the 30° cutter to lower the
valve seat.
* If too low, use the 60° cutter to raise the seat. When
contact area is centered on the valve face, measure
seat width.
* If the seat is too wide or uneven, use both top and
bottom cutters to narrow the seat.
* If the seat is too narrow, widen using the 45° cutter
and re-check contact point on the valve face and seat
width after each cut.
Intake Seat Cutter Diameter:
1.979 in. (50.26 mm)
Exhaust Seat Cutter Diameter:
1.617 in. (41.08 mm)
8. Clean all filings from the area with hot soapy water.
Rinse and dry with compressed air.
9. Lubricate valve guides with clean engine oil and apply
oil or water based lapping compound to the face of
the valve.
NOTICE
Lapping is not required if an interference angle
reconditioning method is used.
10. Insert the valve into its respective guide and lap using
a lapping tool or a section of fuel line connected to the
valve stem.
Summary of Contents for G0-010-00
Page 60: ...2 36 9929758 R01 2019 TAYLOR DUNN G 100 Service Manual Copyright TAYLOR DUNN NOTES MAINTENANCE...
Page 196: ...4 48 9929758 R01 2019 TAYLOR DUNN G 100 Service Manual Copyright TAYLOR DUNN NOTES FUEL SYSTEM...