K-2
K-2
Air Conditioner
9
W701-0160E
2. Large variations in compressor speed
The compressor of a household air conditioner is
maintained at a constant motor speed. The
compressor in a car air conditioner is driven by
the engine, and its speed varies largely.
This means:
The amount of refrigerant circulating in the cycle
varies greatly.
3. For these reasons, the expansion valve is not a
simple throttle valve, but automatically adjusts the
flow in response to changes in the compressor
speed and cooling load, in order to always
maintain the optimal amount of refrigerant in the
cycle.
For this purpose, a receiver is installed to
temporarily store excess refrigerant.
4. In an actual air conditioning system, various
controllers to adjust temperature and airflow are
included to keep the inside of the cab comfortable.
3.6 Receiver functions
1. The receiver is installed between the condenser
and the expansion valve. It temporarily stores the
refrigerant after it has been liquefied by the
condenser, so that the refrigerant can be supplied
as needed to the evaporator according to the
cooling load.
2. Inside the receiver is a strainer and a desiccant,
which remove dust and moisture from the cooling
cycle.
If moisture enters the cycle, it will cause corrosion
of functioning parts, and will freeze in the hole of
the expansion valve, inhibiting the flow of
refrigerant.
3. There are two types of receivers – block joint type
and union type. The difference is the means of
connecting the pipes.
Sight glass
Dryer
Desiccant
Strainer
Strainer
Tube
Desiccant
OUT
IN
OUT
Block joint type
Union type
IN
IW701-0110E08
In addition to temporarily storing the refrigerant,
the receiver also functions to separate gas and
liquid refrigerant.
4. Depending on the outside air conditions, not all of
the refrigerant may be liquefied when it is cooled
by the condenser.
If refrigerant gas is sent to the expansion valve, it
will degrade the cooling capacity.
5. Inside the receiver, liquid refrigerant is stored in
the lower part, while gas refrigerant is stored in
the upper part. Because the receiver exit pipe
takes only liquid refrigerant from the bottom, the
gas and liquid are kept separated.
Gas refrigerant
Liquid refrigerant
IW701-0110E09
Summary of Contents for TT-800XXL1
Page 20: ...B 2 B 2 Hydraulic Pump 3 W101 0280E 1 2 Inside view Variable displacement piston pump...
Page 114: ...5 G 2 G 2 Boom Five Section Boom 5 W536 0760E G 2...
Page 166: ...13 13 W701 0160E K 2 K 2 Air Conditioner K 2 4 Layout 4 1 Overall layout...
Page 167: ...14 14 W701 0160E K 2 K 2 Air Conditioner K 2 4 2 Overall layout...
Page 168: ...15 15 W701 0160E K 2 K 2 Air Conditioner K 2 4 3 Evaporator section...
Page 169: ...16 W701 0160E K 2 K 2 Air Conditioner 5 Compressor ass y...
Page 170: ...17 17 W701 0160E K 2 K 2 Air Conditioner K 2 6 Evaporator ass y...
Page 171: ...18 18 W701 0160E K 2 K 2 Air Conditioner K 2 7 Condenser ass y...
Page 172: ...19 19 W701 0160E K 2 K 2 Air Conditioner K 2 8 Electric 8 1 Electric circuit 0 363 205 60030...
Page 173: ...20 20 W701 0160E K 2 K 2 Air Conditioner K 2 8 2 Main harness A...
Page 174: ...21 21 W701 0160E K 2 K 2 Air Conditioner K 2 8 3 Main harness B...
Page 254: ...Location of Hydraulic Parts 4 WZ07 0780E 4 Z 4 Z 4 Z 4 Location of Hydraulic Parts...
Page 259: ...Hydraulic Electric Carrier Equipment Comparison Table Z 8 Z 8 Z 8 9 WZ09 0130E 9...
Page 263: ...Z 12 Z 12 Harness Boom Z 12 12 WZ04 1310E 12 Harness Boom 1 2 2 343 530 32040 1 343 530 22030...