7
W305-023
1
E
H-2.
H-2.
Boom Length and Angle Detector
2.5 Reassembling potentiometer
1
. Install a new potentiometer.
[NOTICE]
To avoid exposing the potentiometer to high
temperature for a long time, solder the
potentiometer terminal and the lead wires quickly.
Fix the potentiometer terminal including the lead
wires to the bracket using insulating sealant.
Recommended sealant: Shin-Etsu Silicone
KE45RTV (Shin-Etsu Chemicals Industry)
IW305-0230E
1
4
Potentiometer
Bracket
Insulating sealant
2. Loosen the set screws on the reducer side and
potentiometer side to allow both gears to idle.
Check that the gear on the potentiometer side is
spring-returned to the original position after it is
rotated a quarter turn by finger and released. If it
is not returned, loosen the bolt and adjust the
position of the bracket.
IW305-0230E
1
5
Bracket
Spring
Bolt
Gear B
Gear A
3. Fix the gear in the notched section of the speed
reducer shaft using a set screw. Apply thread
locking agent to the set screw.
Tightening torque :
1
.
1
8N-m {0.87ft-lbf}
4. Follow the same procedure as described in the
step
1
2. and below of the "Installing the cord"
section.
2.6 Replacing the boom angle detector
Disconnect the lead wires to the boom angle
detector from the pin terminal section, and replace
the boom angle detector assy.
3. Adjustment
1
. Adjust the cord lock so that the 0-marker on the
cord is on the edge of the cord guide when the
boom is fully retracted.
0-marker
Cord lock
IW305-0230E
1
6
2. Adjust the boom length display of the AML.
(Refer to the repair manual of the AML.)
△
0
36
1
-3
1
9-30000
Summary of Contents for TT-800XXL1
Page 20: ...B 2 B 2 Hydraulic Pump 3 W101 0280E 1 2 Inside view Variable displacement piston pump...
Page 114: ...5 G 2 G 2 Boom Five Section Boom 5 W536 0760E G 2...
Page 166: ...13 13 W701 0160E K 2 K 2 Air Conditioner K 2 4 Layout 4 1 Overall layout...
Page 167: ...14 14 W701 0160E K 2 K 2 Air Conditioner K 2 4 2 Overall layout...
Page 168: ...15 15 W701 0160E K 2 K 2 Air Conditioner K 2 4 3 Evaporator section...
Page 169: ...16 W701 0160E K 2 K 2 Air Conditioner 5 Compressor ass y...
Page 170: ...17 17 W701 0160E K 2 K 2 Air Conditioner K 2 6 Evaporator ass y...
Page 171: ...18 18 W701 0160E K 2 K 2 Air Conditioner K 2 7 Condenser ass y...
Page 172: ...19 19 W701 0160E K 2 K 2 Air Conditioner K 2 8 Electric 8 1 Electric circuit 0 363 205 60030...
Page 173: ...20 20 W701 0160E K 2 K 2 Air Conditioner K 2 8 2 Main harness A...
Page 174: ...21 21 W701 0160E K 2 K 2 Air Conditioner K 2 8 3 Main harness B...
Page 254: ...Location of Hydraulic Parts 4 WZ07 0780E 4 Z 4 Z 4 Z 4 Location of Hydraulic Parts...
Page 259: ...Hydraulic Electric Carrier Equipment Comparison Table Z 8 Z 8 Z 8 9 WZ09 0130E 9...
Page 263: ...Z 12 Z 12 Harness Boom Z 12 12 WZ04 1310E 12 Harness Boom 1 2 2 343 530 32040 1 343 530 22030...