144
SVAN 977C User Manual
Slope +
Type of trigger that starts the measurement/integration
by the duration of the
Integration Period
on condition:
rising value of the RMS result (
Source
) integrated during
0,5 ms passes above the threshold value (Level).
Chapter
Slope -
Type of trigger that starts the measurement/integration
by the duration of the
Integration Period
on condition:
falling value of the RMS result (
Source
) integrated during
0,5 ms passes below the threshold value (Level).
Chapter
Level +
Type of trigger that starts the 1-second measurement/
integration on condition: value of the RMS result (
Source
)
integrated during 0,5 ms is greater than the threshold
value (
Level
). In other cases, the instrument continues
checking the trigger condition every 0,5 mc. During one
measurement cycle the instrument performs as many 1-
second
integrations
as
many
seconds
the
Integration Period
consists and stops the measurement
cycle.
Chapter
Level -
Type of trigger that starts the 1-second measurement/
integration on condition: value of the RMS result (
Source
)
integrated during 0,5 ms is lower than the threshold value
(
Level
). In other cases, the instrument continues
checking the trigger condition every 0,5 mc. During one
measurement cycle the instrument performs as many 1-
second
integrations
as
many
seconds
the
Integration Period
consists and stops the measurement
cycle.
Chapter
Grad +
Type of trigger that starts the 1-second measurement/
integration on condition: value of the RMS result (
Source
)
integrated during 0,5 ms is greater than the threshold
value (Level) and the gradient of this Source is greater
than the threshold level (
Gradient
). In other cases, the
instrument continues checking the trigger condition every
0,5 mc. During one measurement cycle the instrument
performs as many 1-second integrations as many
seconds the
Integration Period
consists and stops the
measurement cycle.
This type of trigger has the same logic as
Level +
trigger,
but the trigger condition requires also gradient level to be
exceeded.
Chapter
External
Type of trigger that starts the measurement/integration
when the trigger signal appears on the I/O socket of the
instrument. After the measurement/ integration start from
the trigger, the measurement/integration will continue by
the
Integration Period
.
Chapter
Source
Measured result that is compared with the threshold
value (Level) for triggering
– RMS measured in the first
profile: Leq(1) in sound modes and RMS(1) in vibration
modes.
Chapter
Summary of Contents for Shawcity SVAN 977C
Page 231: ...231 SVAN 977C User Manual Appendixes 630 Hz 800 Hz 1000 Hz 1250 Hz 1600 Hz 2000 Hz...
Page 232: ...232 SVAN 977C User Manual Appendixes 2240 Hz 2500 Hz 2800 Hz 3150 Hz 3550 Hz 4000 Hz...
Page 233: ...233 SVAN 977C User Manual Appendixes 4500 Hz 5000 Hz 5600 Hz 6300 Hz 7100 Hz 8000 Hz...
Page 234: ...234 SVAN 977C User Manual Appendixes 8500 Hz 9000 Hz 9500 Hz 10000 Hz 10600 Hz 11200 Hz...
Page 242: ...242 SVAN 977C User Manual Appendixes 250 Hz 315 Hz 400 Hz 500 Hz 630 Hz 800 Hz...
Page 243: ...243 SVAN 977C User Manual Appendixes 1000 Hz 1250 Hz 1600 Hz 2000 Hz 2240 Hz 2500 Hz...
Page 244: ...244 SVAN 977C User Manual Appendixes 2800 Hz 3150 Hz 3550 Hz 4000 Hz 4500 Hz 5000 Hz...
Page 245: ...245 SVAN 977C User Manual Appendixes 5600 Hz 6300 Hz 7100 Hz 8000 Hz 8500 Hz 9000 Hz...
Page 246: ...246 SVAN 977C User Manual Appendixes 9500 Hz 10000 Hz 10600 Hz 11200 Hz 11800 Hz 12500 Hz...
Page 250: ...250 SVAN 977C User Manual Appendixes...
Page 336: ...336 SVAN 977C User Manual Appendixes O ring gasket locations inside...