COOLING AND LUBRICATION SYSTEM 7-9
COOLING FAN THERMO-SWITCH
REMOVAL
• Drain the engine coolant. (
2-17)
• Disconnect the cooling fan thermo-switch coupler
1
.
• Remove the cooling fan thermo-switch
2
.
INSPECTION
• Check the thermo-switch closing or opening temperatures by
testing it at the bench as shown in the figure. Connect the
thermo-switch to a circuit tester and place it in the oil con-
tained in a pan, which is placed on a stove.
• Heat the oil to raise its temperature slowly, and read the col-
umn thermometer when the switch closes or opens.
09900-25008: Multi circuit tester set
Tester knob indication: Continuity test (
)
Cooling fan thermo-switch operating temperature:
Standard (OFF
→
ON): Approx. 105 °C (221 °F)
(ON
→
OFF): Approx. 100 °C (212 °F)
INSTALLATION
• Install the O-ring
1
.
• Tighten the cooling fan thermo-switch to the specified torque.
Cooling fan thermo-switch:
17 N·m (1.7 kgf-m, 12.5 lb-ft)
• Bleed air from the cooling circuit. (
2-18)
* Take special care when handling the thermo-switch.
It may cause damage if it gets a sharp impact.
* Do not contact the cooling fan thermo-switch
1
and
the column thermometer
2
with a pan.
Oil
SA
MP
LE
Summary of Contents for Boulevard M50
Page 1: ...VZ800 9 9 5 0 0 3 8 0 5 0 0 1 E...
Page 42: ...2 26 PERIODIC MAINTENANCE SAMPLE...
Page 413: ...SERVICING INFORMATION 10 25 LUBRICATION POINTS 5 3 mm 2 1 in SAMPLE...
Page 414: ...10 26 SERVICING INFORMATION FUEL TANK INSTALLATION 1 Cut after clamping 2 Frame Inside SAMPLE...
Page 418: ...10 30 SERVICING INFORMATION LEFT SIDE COVER INSTALLATION SAMPLE...
Page 453: ...Prepared by December 2004 Part No 99500 38050 01E Printed in Japan 456 SAMPLE...
Page 454: ......