5-46 FI SYSTEM
ECT SENSOR INSPECTION
• Remove the ECT sensor. (
5-77)
• Check the ECT sensor by testing it at the bench as shown in
the figure. Connect the ECT sensor
1
to a circuit tester and
place it in the oil
2
contained in a pan, which is placed on a
stove.
• Heat the oil to raise its temperature slowly and read the col-
umn thermometer
3
and the ohmmeter.
• If the ECT sensor ohmic value does not change in the propor-
tion indicated, replace it with a new one.
ECT sensor specification
09900-25008: Multi-circuit tester set
Tester knob indication: Resistance (
Ω
)
If the resistance is noted to show infinity or too much different
resistance value, replace the ECT sensor with a new one.
Engine Coolant Temp
Resistance
20 °C (68 °F)
Approx. 2.45 k
Ω
40 °C (104 °F)
Approx. 1.148 k
Ω
60 °C (140 °F)
Approx. 0.587 k
Ω
80 °C (176 °F)
Approx. 0.322 k
Ω
* Take special care when handling the ECT sensor. It
may cause damage if it gets a sharp impact.
* Do not contact the ECT sensor and the column ther-
mometer with a pan.
SA
MP
LE
Summary of Contents for Boulevard M50
Page 1: ...VZ800 9 9 5 0 0 3 8 0 5 0 0 1 E...
Page 42: ...2 26 PERIODIC MAINTENANCE SAMPLE...
Page 413: ...SERVICING INFORMATION 10 25 LUBRICATION POINTS 5 3 mm 2 1 in SAMPLE...
Page 414: ...10 26 SERVICING INFORMATION FUEL TANK INSTALLATION 1 Cut after clamping 2 Frame Inside SAMPLE...
Page 418: ...10 30 SERVICING INFORMATION LEFT SIDE COVER INSTALLATION SAMPLE...
Page 453: ...Prepared by December 2004 Part No 99500 38050 01E Printed in Japan 456 SAMPLE...
Page 454: ......