FI SYSTEM 5-27
MALFUNCTION CODE AND DEFECTIVE CONDITION
DTC No.
DETECTED
ITEM
DETECTED FAILURE CONDITION
CHECK FOR
C00
NO FAULT
–––––––––––
–––––––––––
C12
CKP sensor
The signal does not reach ECM for 3
sec. or more, after receiving the starter
signal.
CKP sensor wiring and mechan-
ical parts
CKP sensor, lead wire/coupler
connection
P0335
C13/C17
IAP sensor
The sensor should produce following
voltage.
0.1 V
sensor voltage < 4.8 V
In other than the above range, C13
(P1750) or C17 (P0105) is indicated.
IAP sensor, lead wire/coupler
connection
P1750/P0105
C14
TP sensor
The sensor should produce following
voltage.
0.1 V
sensor voltage < 4.8 V
In other than the above range, C14
(P0120) is indicated.
TP sensor, lead wire/coupler
connection
P0120
H
Sensor voltage is higher than specified
value.
TP sensor circuit shorted to
VCC or ground circuit open
L
Sensor voltage is lower than specified
value.
TP sensor circuit open or
shorted to ground or VCC circuit
open
C15
ECT sensor
The sensor voltage should be the fol-
lowing.
0.1 V
sensor voltage < 4.6 V
In other than the above range, C15
(P0115) is indicated.
ECT sensor, lead wire/coupler
connection
P0115
H
Sensor voltage is higher than specified
value.
ECT sensor circuit open or
ground circuit open
L
Sensor voltage is lower than specified
value.
ECT sensor circuit shorted to
ground
SA
MP
LE
Summary of Contents for Boulevard M50
Page 1: ...VZ800 9 9 5 0 0 3 8 0 5 0 0 1 E...
Page 42: ...2 26 PERIODIC MAINTENANCE SAMPLE...
Page 413: ...SERVICING INFORMATION 10 25 LUBRICATION POINTS 5 3 mm 2 1 in SAMPLE...
Page 414: ...10 26 SERVICING INFORMATION FUEL TANK INSTALLATION 1 Cut after clamping 2 Frame Inside SAMPLE...
Page 418: ...10 30 SERVICING INFORMATION LEFT SIDE COVER INSTALLATION SAMPLE...
Page 453: ...Prepared by December 2004 Part No 99500 38050 01E Printed in Japan 456 SAMPLE...
Page 454: ......