4-6
Sun Fire X4440 Server Service Manual • September 2010
FIGURE 4-2
DDR2 DIMM Layout
4.1.2.1
DDR2 DIMM Placement
Refer to the service label on the cover for DDR2 DIMM placement information. Refer
to the
Sun Fire X4140, X4240, and X4440 Servers Diagnostics Guide
for additional DDR2
DIMM information.
The DIMM population rules for the server are as follows:
■
Each CPU can support a maximum of eight DIMMs.
■
The DIMM slots are paired and the DIMMs must be installed in pairs (0-1, 2-3, 4-5, and
6-7). The memory sockets are colored black
or white to indicate which slots are
paired by matching colors.