Chapter 4
Servicing Motherboard Components
4-47
FIGURE 4-21
Installing a CPU- part 2
4.8.4
Installing an XOption CPU
1. Prepare the server for service.
a. Power off the server.
See
Section 2.5, “Powering Off the Server” on page 2-4
.
b. Disconnect the power cord (or cords) from the power supply (or supplies).
See
Section 2.5, “Powering Off the Server” on page 2-4
.
c. Slide the server out of the rack.
See
Section 2.7, “Removing a Server From the Rack” on page 2-8
.
d. Attach an antistatic wrist strap.
See
Section 2.8, “Performing Electrostatic Discharge and Antistatic Prevention
Measures” on page 2-10
.