Chapter 4
Servicing Motherboard Components
4-55
a. BMC Firmware Revision is correct on the Main page.
b. Status of BMC is working in Advanced -> IPMI 2.0 Configuration page.
10. Exit BIOS and start the operating system.
4.11
Using the Reset and NMI Switches
Caution –
Do not use the Reset and NMI Dump switches unless you are instructed
to do so by a Field Service engineer.
4.11.1
Reset Switch
The Reset switch on the motherboard sends a reset order to the CPUs, resetting the
main system, but not the service processor. The button for this switch is one of the 3
hidden (recessed) buttons on the back of the motherboard located between the NET
MGT and NET0 connectors and closest to NET0. It can be pushed by sticking a
paper clip or similar object through the hole provided on the rear of the chassis.
4.11.2
NMI Dump Switch
The NMI button is the center button of the row of 3 hidden (recessed) buttons on the
back of the motherboardlocated between the NET MGT and NET0 connectors. The
button for this switch can be pushed by sticking a paper clip or similar object
through the hole provided on the rear of the chassis.
The Non-Maskable Interrupt (NMI) Dump switch sends an NMI order to the CPUs,
which is used by Field Service for debugging activities at the request of operating
system engineers. NMI can also be asserted by ILOM. Refer to the
Sun Integrated
Lights Out Manager 2.0 User's Guide
.
4.12
Upgrading Two Socket to Four Socket
To convert the Sun Fire X4440 motherboard from a two socket configuration to a four
socket configuration, do the following.
Summary of Contents for Fire X4440
Page 1: ...Sun Fire X4440 Server Service Manual Part No 820 3836 14 September 2010 Revision 01 ...
Page 10: ...x Sun Fire X4440 Server Service Manual September 2010 ...
Page 20: ...1 6 Sun Fire X4440 Server Service Manual September 2010 FIGURE 1 1 Cables SAS ...
Page 39: ...Chapter 2 Preparing to Service the System 2 13 ...
Page 40: ...2 14 Sun Fire X4440 Server Service Manual September 2010 ...
Page 64: ...3 24 Sun Fire X4440 Server Service Manual September 2010 ...
Page 84: ...4 20 Sun Fire X4440 Server Service Manual September 2010 FIGURE 4 9 Installing the Air Duct ...
Page 94: ...4 30 Sun Fire X4440 Server Service Manual September 2010 FIGURE 4 14 Installing a PCIe Card ...
Page 122: ...4 58 Sun Fire X4440 Server Service Manual September 2010 ...
Page 179: ...Chapter 6 Returning the Server to Operation 6 7 ...
Page 180: ...6 8 Sun Fire X4440 Server Service Manual September 2010 ...