Chapter 4
Servicing Motherboard Components
4-23
FIGURE 4-10
Removing a PCIe Riser
4.4.2
Installing a PCIe Riser
Caution –
Ensure that all power is removed from the server before removing or
installing risers. You must disconnect the power cables before performing this
procedure.
1. Lower the PCIe riser and any cards attached to the PCIe riser into the system.
2. Slide the back of the riser into the motherboard rear panel stiffener.
3. Tighten the screw that secures the riser to the motherboard. (
FIGURE 4-11
[1])
4. Install the rear panel PCI crossbeam. [2]
a. Slide the crossbeam down over the PCIe risers.
b. Secure the PCI crossbeam is secured with two captive Phillips screws.
5. Return the server to operation.
a. Install the top cover.
See
Section 6.1, “Installing the Top Cover” on page 6-2
.
b. Connect any data cables to the PCIe card.
Route data cables through the cable management arm.
Summary of Contents for Fire X4440
Page 1: ...Sun Fire X4440 Server Service Manual Part No 820 3836 14 September 2010 Revision 01 ...
Page 10: ...x Sun Fire X4440 Server Service Manual September 2010 ...
Page 20: ...1 6 Sun Fire X4440 Server Service Manual September 2010 FIGURE 1 1 Cables SAS ...
Page 39: ...Chapter 2 Preparing to Service the System 2 13 ...
Page 40: ...2 14 Sun Fire X4440 Server Service Manual September 2010 ...
Page 64: ...3 24 Sun Fire X4440 Server Service Manual September 2010 ...
Page 84: ...4 20 Sun Fire X4440 Server Service Manual September 2010 FIGURE 4 9 Installing the Air Duct ...
Page 94: ...4 30 Sun Fire X4440 Server Service Manual September 2010 FIGURE 4 14 Installing a PCIe Card ...
Page 122: ...4 58 Sun Fire X4440 Server Service Manual September 2010 ...
Page 179: ...Chapter 6 Returning the Server to Operation 6 7 ...
Page 180: ...6 8 Sun Fire X4440 Server Service Manual September 2010 ...