4-46
Sun Fire X4440 Server Service Manual • September 2010
FIGURE 4-20
Required Pattern for Thermal Grease Application
10. Smooth the grease into a thin even layer on top of the CPU. (
FIGURE 4-21
)
You can use a piece of plastic bag over your finger.
11. Orient the heat sink so that the two screws line up with the mounting inserts.
Ensure that the heat sink is oriented so that the"DIMM SIDE" label on the heat
sink is next to the DIMMs.
12. Tighten the two screws alternately one half turn until fully seated.
Each screw
must
be turned no more than one 1/2 turn before moving over to the
other screw and doing the same. Continue to turn each screw one 1/2 turn,
moving back and forth between the two screws until both screws are tightened.
13. Reinstall the mezzanine tray.
See
Section 4.2.2, “Installing the Mezzanine Tray” on page 4-14
.
14. Return the server to operation.
a. Install the top cover.
See
Section 6.1, “Installing the Top Cover” on page 6-2
.
b. Install the server into the rack.
See
Section 6.2, “Reinstalling the Server in the Rack” on page 6-3
.
c. Reconnect the power cord (or cords) to the power supply (or supplies).
Verify that the AC Present LED is lit.
See
Section 6.4, “Powering On the Server” on page 6-6
.
d. Power on the server.
See
Section 6.4, “Powering On the Server” on page 6-6
.
Summary of Contents for Fire X4440
Page 1: ...Sun Fire X4440 Server Service Manual Part No 820 3836 14 September 2010 Revision 01 ...
Page 10: ...x Sun Fire X4440 Server Service Manual September 2010 ...
Page 20: ...1 6 Sun Fire X4440 Server Service Manual September 2010 FIGURE 1 1 Cables SAS ...
Page 39: ...Chapter 2 Preparing to Service the System 2 13 ...
Page 40: ...2 14 Sun Fire X4440 Server Service Manual September 2010 ...
Page 64: ...3 24 Sun Fire X4440 Server Service Manual September 2010 ...
Page 84: ...4 20 Sun Fire X4440 Server Service Manual September 2010 FIGURE 4 9 Installing the Air Duct ...
Page 94: ...4 30 Sun Fire X4440 Server Service Manual September 2010 FIGURE 4 14 Installing a PCIe Card ...
Page 122: ...4 58 Sun Fire X4440 Server Service Manual September 2010 ...
Page 179: ...Chapter 6 Returning the Server to Operation 6 7 ...
Page 180: ...6 8 Sun Fire X4440 Server Service Manual September 2010 ...