5-48
Sun Fire X4440 Server Service Manual • September 2010
a. Power off the server.
See
Section 2.5, “Powering Off the Server” on page 2-4
.
b. Disconnect the power cord (or cords) from the power supply (or supplies).
See
Section 2.5, “Powering Off the Server” on page 2-4
.
c. Slide the server out of the rack.
See
Section 2.7, “Removing a Server From the Rack” on page 2-8
.
d. Attach an antistatic wrist strap.
See
Section 2.8, “Performing Electrostatic Discharge and Antistatic Prevention
Measures” on page 2-10
.
e. Remove the top cover.
See
Section 2.9, “Removing the Top Cover” on page 2-12
.
2. Remove the HBA card from slot 0 (
FIGURE 5-26
)
See
Section 4.5.2, “Removing PCIe Cards” on page 4-26
.
3. Remove the PCIe card from slot 2, if present, to access the onboard SATA
connector.
Skip this step if no card is present in slot 2.
4. Disconnect the drive cable from the onboard SATA connector (left) (SATA #2).
5. Remove all fan modules.
See
Section 3.5.4, “Removing a Fan Module” on page 3-13
.
6. Remove the fan power boards.
See
Section 5.1.1, “Removing a Fan Power Board” on page 5-2
.
7. Remove the cable from the drive backplane on the right side.
8. Obtain the short cable (PN 530-3895) from the accessory pack.
9. Attach the short cable to right side drives backplane.
10. Disconnect the drive cable from the 0~3 connector (SATA #1).
11. Install the HBA in slot 0.
See
Section 4.5.3, “Installing PCIe Cards” on page 4-28
.
12. Connect the left cable to connector 0 on the HBA card.
13. Connect the right cable to connector 1 on the HBA card.
Align properly. Rout the cables carefully through the server.
See
Section 1.2.2, “System Cables” on page 1-5
.
Summary of Contents for Fire X4440
Page 1: ...Sun Fire X4440 Server Service Manual Part No 820 3836 14 September 2010 Revision 01 ...
Page 10: ...x Sun Fire X4440 Server Service Manual September 2010 ...
Page 20: ...1 6 Sun Fire X4440 Server Service Manual September 2010 FIGURE 1 1 Cables SAS ...
Page 39: ...Chapter 2 Preparing to Service the System 2 13 ...
Page 40: ...2 14 Sun Fire X4440 Server Service Manual September 2010 ...
Page 64: ...3 24 Sun Fire X4440 Server Service Manual September 2010 ...
Page 84: ...4 20 Sun Fire X4440 Server Service Manual September 2010 FIGURE 4 9 Installing the Air Duct ...
Page 94: ...4 30 Sun Fire X4440 Server Service Manual September 2010 FIGURE 4 14 Installing a PCIe Card ...
Page 122: ...4 58 Sun Fire X4440 Server Service Manual September 2010 ...
Page 179: ...Chapter 6 Returning the Server to Operation 6 7 ...
Page 180: ...6 8 Sun Fire X4440 Server Service Manual September 2010 ...