Chapter 4
Servicing Motherboard Components
4-9
FIGURE 4-4
Removing DDR2 DIMM
7. Place the DDR2 DIMM on an antistatic mat.
8. Repeat
Step 5
through
Step 7
to remove any additional DDR2 DIMMs.
4.1.4
Installing DDR2 DIMMs
Caution –
Ensure that all power is removed from the server before removing or
installing DDR2 DIMMs, or damage to the DDR2 DIMM might occur. You must
disconnect all power cables from the system before performing this procedure.
Tip –
See
Section 4.1.2, “DDR2 DIMM Guidelines” on page 4-5
for information about
configuring the DDR2 DIMMs.
1. Unpack the replacement DDR2 DIMMs and place them on an antistatic mat.
2. Ensure that the ejector tabs are in the open position.
3. Line up the replacement DDR2 DIMM with the connector (
FIGURE 4-5
).
Align the DDR2 DIMM notch with the key in the connector. This ensures that the
DDR2 DIMM is oriented correctly.
Summary of Contents for Fire X4440
Page 1: ...Sun Fire X4440 Server Service Manual Part No 820 3836 14 September 2010 Revision 01 ...
Page 10: ...x Sun Fire X4440 Server Service Manual September 2010 ...
Page 20: ...1 6 Sun Fire X4440 Server Service Manual September 2010 FIGURE 1 1 Cables SAS ...
Page 39: ...Chapter 2 Preparing to Service the System 2 13 ...
Page 40: ...2 14 Sun Fire X4440 Server Service Manual September 2010 ...
Page 64: ...3 24 Sun Fire X4440 Server Service Manual September 2010 ...
Page 84: ...4 20 Sun Fire X4440 Server Service Manual September 2010 FIGURE 4 9 Installing the Air Duct ...
Page 94: ...4 30 Sun Fire X4440 Server Service Manual September 2010 FIGURE 4 14 Installing a PCIe Card ...
Page 122: ...4 58 Sun Fire X4440 Server Service Manual September 2010 ...
Page 179: ...Chapter 6 Returning the Server to Operation 6 7 ...
Page 180: ...6 8 Sun Fire X4440 Server Service Manual September 2010 ...