Chapter 3
Servicing Customer-Replaceable Devices
3-17
3.6.3
Removing a Power Supply
If space is limited behind the server, you might need to remove the server from the
rack. See
Section 2.7, “Removing a Server From the Rack” on page 2-8
.
Caution –
Hazardous voltages are present. To reduce the risk of electric shock and
danger to personal health, follow the instructions.
1. Determine which power supply (0 or 1) requires replacement.
A lit (amber) failure LED on a power supply indicates that a failure was detected.
2. Gain access to the rear of the server where the faulty power supply is located.
3. Release the cable management arm (CMA). (
FIGURE 3-12
)
The CMA is located at the rear of the server rack.
a. Press and hold the tab.
b. Rotate the cable management arm out of the way so that you can access the
power supply.
Figure Legend
Legend
LED
Symbol
Color
Lights when
1
AC Present
Green
The power supply is plugged in and
AC power is available, regardless of
system power state.
2
Service Required
Amber
The power supply is faulty.
The front and rear panel Service
Required LEDs are also lit if the
system detects a power supply fault.
3
OK to Remove
Green
A power supply can be removed
safely during a hot–swap operation.
Summary of Contents for Fire X4440
Page 1: ...Sun Fire X4440 Server Service Manual Part No 820 3836 14 September 2010 Revision 01 ...
Page 10: ...x Sun Fire X4440 Server Service Manual September 2010 ...
Page 20: ...1 6 Sun Fire X4440 Server Service Manual September 2010 FIGURE 1 1 Cables SAS ...
Page 39: ...Chapter 2 Preparing to Service the System 2 13 ...
Page 40: ...2 14 Sun Fire X4440 Server Service Manual September 2010 ...
Page 64: ...3 24 Sun Fire X4440 Server Service Manual September 2010 ...
Page 84: ...4 20 Sun Fire X4440 Server Service Manual September 2010 FIGURE 4 9 Installing the Air Duct ...
Page 94: ...4 30 Sun Fire X4440 Server Service Manual September 2010 FIGURE 4 14 Installing a PCIe Card ...
Page 122: ...4 58 Sun Fire X4440 Server Service Manual September 2010 ...
Page 179: ...Chapter 6 Returning the Server to Operation 6 7 ...
Page 180: ...6 8 Sun Fire X4440 Server Service Manual September 2010 ...