5-6
Sun Fire X4440 Server Service Manual • September 2010
c. Remove the server from the rack.
See
Section 2.7, “Removing a Server From the Rack” on page 2-8
.
d. Attach an antistatic wrist strap.
See
Section 2.8, “Performing Electrostatic Discharge and Antistatic Prevention
Measures” on page 2-10
.
e. Remove the top cover.
See
Section 2.9, “Removing the Top Cover” on page 2-12
.
2. If you are servicing the drives backplane, remove all drives.
See
Section 3.2.3, “Removing a Drive” on page 3-4
.
Note –
Make a note of the drive locations before removing them from the system.
You will need to install the drives in the correct locations when reassembling the
system.
3. If you are servicing the drives backplane, remove the DVD/USB module.
See
Section 3.7.1, “Removing the DVD/USB Module” on page 3-22
.
4. Remove the fan modules.
See
Section 3.5.4, “Removing a Fan Module” on page 3-13
.
5. Remove the No. 2 Phillips screws securing the drives cage to the chassis.
(
FIGURE 5-3
[1] and [2])
Two screws secure the disk cage to each side of the chassis.
6. Slide the drives cage forward to disengage the backplane from the Paddle cards.
(
FIGURE 5-3
[3])
7. Lift the drives cage up and disconnect the drives data cables. (
FIGURE 5-3
[4])
Press the connector release button to release the cable.
8. Set the drives cage on an antistatic mat.
Summary of Contents for Fire X4440
Page 1: ...Sun Fire X4440 Server Service Manual Part No 820 3836 14 September 2010 Revision 01 ...
Page 10: ...x Sun Fire X4440 Server Service Manual September 2010 ...
Page 20: ...1 6 Sun Fire X4440 Server Service Manual September 2010 FIGURE 1 1 Cables SAS ...
Page 39: ...Chapter 2 Preparing to Service the System 2 13 ...
Page 40: ...2 14 Sun Fire X4440 Server Service Manual September 2010 ...
Page 64: ...3 24 Sun Fire X4440 Server Service Manual September 2010 ...
Page 84: ...4 20 Sun Fire X4440 Server Service Manual September 2010 FIGURE 4 9 Installing the Air Duct ...
Page 94: ...4 30 Sun Fire X4440 Server Service Manual September 2010 FIGURE 4 14 Installing a PCIe Card ...
Page 122: ...4 58 Sun Fire X4440 Server Service Manual September 2010 ...
Page 179: ...Chapter 6 Returning the Server to Operation 6 7 ...
Page 180: ...6 8 Sun Fire X4440 Server Service Manual September 2010 ...