Netra ft 1800 Installation Guide • February 1999
In the following procedure, you use
cmsconfig
to obtain the
Disk
attribute of the
HDD module and the
Funct_0
attribute of the CD-ROM drive (plus
Funct_1
if you
have an additional drive).
To identify the device name of the root disk:
1. Start
cmsconfig:
2. Locate the HDD modules in the list.
You can press
p
to page down to see second and subsequent pages.
3. For each HDD module in the list:
a. Enter the number next to the module.
The attributes of the module are displayed.
b. Note the
Disk
attribute of the module.
This is a normal Solaris device name.
c. Press
q
to return to the list of modules
4. For each RMM module in the list:
a. Enter the number next to the module.
The attributes of the module are displayed.
b. Note the
Funct_0
attribute of the module.
This is the device name of the CD-ROM drive. It is a normal Solaris device name.
If there is a second CD-ROM drive in the module, note the
Funct_1
attribute.
This is the device name of the second CD-ROM drive. It is a normal Solaris device
name.
c. Press
q
twice to exit
cmsconfig
.
You will need this information when you initialize the Volume Manager. It can be
useful for other purposes, so you may wish to keep it.
You should install the Volume Manager after the Netra ft 1800 software and any
required patches, and before other applications. You should also configure the
Volume Manager volumes before you install other applications.
Before you install Sun StorEdge Volume Manager, copy the file
/etc/vfstab
to
/
etc/vfstab.prevm
. This standard practice helps Sun support engineers to recover
a system in the very rare event of serious system failure.
# /usr/platform/SUNW,Ultra-4FT/SUNWcms/sbin/cmsconfig
Summary of Contents for Netra ft 1800
Page 6: ...vi Netra ft 1800 Installation Guide February 1999 ...
Page 10: ...x Netra ft 1800 Installation Guide February 1999 ...
Page 40: ...26 Netra ft 1800 Installation Guide February 1999 FIGURE 2 12 Removing a CPUset Module ...
Page 41: ...Chapter 2 Hardware Installation 27 CAF Modules FIGURE 2 13 Removing a CAF ...
Page 43: ...Chapter 2 Hardware Installation 29 PSU Modules FIGURE 2 15 Removing a Power Supply ...
Page 45: ...Chapter 2 Hardware Installation 31 FIGURE 2 16 Removing an RMM Module ...
Page 56: ...42 Netra ft 1800 Installation Guide February 1999 ...