Netra ft 1800 Installation Guide • February 1999
Before You Start
Caution –
Before inserting a CD-ROM disk into your system read “Handling and
Taking Care of your CD-ROM Disks” in the Netra ft 1800 Compliance and Safety
Manual. In some circumstances if your CD-ROM disk does not have a clean data
surface your system may fail to boot.
1. Establish the following:
■
The system Ethernet address (displayed in the BOOT PROM messages at system
startup, which you can display with the
banner
utility, invoked from the
ok
prompt).
■
The system IP address (see your system administrator).
■
The machine name (see your system administrator).
■
The netmask (see your system administrator).
■
The name service (for example, NIS or NIS+; see your system administrator).
2. You need to be at the OBP
ok
prompt in order to perform the installation.
▼
To Install the Software
This section describes the steps necessary to install a Netra ft 1800 system with the
Solaris operating environment and Netra ft 1800 software.
Note –
It is recommended that you install Solaris on one hard disk only in order to
optimize the performance of the Volume Manager.
1. Disengage all the hard disk drive modules except the one in the location on which
you wish to install the operating environment.
See
FIGURE 2-17
on page 2-33. You do not need to remove the modules from their
slots completely.
2. If the system is powered down, power on the system.
See “To Power On the System” on page 55.
3. Perform Step a for network installation or Step b for local installation.
a. Set up an install server with the Netra ft 1800 CD-ROM
Follow the procedures outlined in Chapter 7 of the Solaris Advanced Installation
Guide (part number 802-5740-10).
!
Summary of Contents for Netra ft 1800
Page 6: ...vi Netra ft 1800 Installation Guide February 1999 ...
Page 10: ...x Netra ft 1800 Installation Guide February 1999 ...
Page 40: ...26 Netra ft 1800 Installation Guide February 1999 FIGURE 2 12 Removing a CPUset Module ...
Page 41: ...Chapter 2 Hardware Installation 27 CAF Modules FIGURE 2 13 Removing a CAF ...
Page 43: ...Chapter 2 Hardware Installation 29 PSU Modules FIGURE 2 15 Removing a Power Supply ...
Page 45: ...Chapter 2 Hardware Installation 31 FIGURE 2 16 Removing an RMM Module ...
Page 56: ...42 Netra ft 1800 Installation Guide February 1999 ...