Note –
The Sun Blade X6275 M2 Server module is a dual-node server. If necessary, use this
procedure for
both
nodes.
■
See
“How to Remove the Energy Storage Modules” on page 50
.
■
See
“Removing and Installing Flash Modules” on page 46
.
Prepare the server module for service. See
“Preparing the Server for Service”on page 25
.
Position the rear ESM in the empty holder with the cable facing up and toward the rear of the
server.
Slide the ESM into the holder and guide the cable into the cable slot on the back side of the
holder.
Position the front ESM in the empty holder with the cable facing up and toward the front of the
server.
Slide the ESM into the holder and guide the cable into the cable slot on the front of the holder.
Before You Begin
1
2
3
4
5
Removing and Installing the Energy Storage Modules
Sun Blade X6275 M2 Server Module Service Manual • March, 2013
52