How to Install DIMMs
Note –
This component is a customer-replaceable unit (CRU).
Always replace a DIMM with the same Oracle part number as the failed DIMM.
Note –
The Sun Blade X6275 M2 Server module is a dual-node server. If necessary, use this
procedure for
both
nodes.
■
“How to Remove DIMMs” on page 44
.
■
“DIMM Slot Designations and Population Order” on page 42
■
“DIMM Population Rules and Guidelines for the Sun Blade X6275 M2 Server module” on
page 43
Prepare the server module for service. See
“How to Prepare the Server Module for Service”on
page 25
.
Ensure that the ejector tabs are in the open position.
Line up the replacement DIMM with the connector.
Align the DIMM notch with the key in the connector. This ensures that the DIMM is oriented
correctly.
Push the DIMM into the slot until the ejector tabs lift and lock the DIMM in place.