Caution –
Component damage can occur if the FMods are removed or installed when the Charge
Status LED is lit. Wait for the LED to turn off before removing or installing FMods.
Note –
The Sun Blade X6275 M2 Server module is a dual-node server. If necessary, use this
procedure for
both
nodes.
See
“Illustrated Parts Breakdown” on page 15
for the location of the flash modules.
If necessary, back up any data that is contained on the Flash Module (FMod).
Prepare the server module for service. See
“Preparing the Server for Service”on page 25
.
Locate the FMod slot on the motherboard.
A lit green LED next to an FMod slot indicates that the FMod slot is powered on by the energy
storage module (ESM). It does
not
indicate a faulty FMod. The ESM must drain before you can
remove the FMod. Wait until the green FMod LED is off
before
removing or installing an FMod.
Before You Begin
1
2
3
Removing and Installing Flash Modules
47