Wait for the green FMod LED to turn off (about 20 seconds).
Rotate both FMod slot ejectors outward as far as they will go.
This action partially ejects the FMod from the slot.
Carefully lift the FMod straight up to remove it from the slot.
See frame [3] of the illustration in
Step 3
.
Prepare the server module for operation. See
“How to Prepare the Server Module for Operation”
on page 34
.
“How to Install Flash Modules” on page 48
▼
How to Install Flash Modules
Note –
This component is a customer-replaceable unit (CRU).
Two Flash Module (FMod) slots are located on the server module motherboard. FMod power is
supplied by the charge stored on the energy storage modules (ESMs). When the server is
removed from the power source (the chassis), the ESMs slowly lose their charge.
A Charge Status LED on the motherboard indicates the status of the charge. When the LED is
off, the ESMs are not charged. When the LED is on, the ESMs are charged. It is not safe to
remove or install the FMods when the ESMs have a charge. Wait until the Charge Status LED is
off.
Caution –
Component damage can occur if the FMods are removed or installed when the Charge
Status LED is lit. Wait for the LED to turn off before removing or installing FMods.
Note –
The Sun Blade X6275 M2 Server module is a dual-node server. If necessary, use this
procedure for
both
nodes.
See
“How to Remove Flash Modules” on page 46
.
Unpack the replacement flash modules and place them on an antistatic mat.
Prepare the server module for service. See
“How to Prepare the Server Module for Service”on
page 25
.
4
5
6
7
Next Steps
Before You Begin
1
2
Removing and Installing Flash Modules
Sun Blade X6275 M2 Server Module Service Manual • March, 2013
48