Caution –
Do not install a server module into the chassis until at least 20 seconds has elapsed
since the server module was disengaged from the chassis mid-plane connector.
See
“Preparing the Server for Service” on page 25
.
Power off both server module compute nodes or place them in standby power mode. See
“How
to Power Off the Server Module”on page 23
.
For information about power modes, see
“Power Modes” on page 19
.
Squeeze and hold green ejector buttons.
To unseat the server module, rotate both ejector arms away from the server module at the same
time until fully extended.
Caution –
Possible component damage or personal injury. Do
not
attempt to remove the server
module using only the ejector levers.
To
partially
remove the server module from the chassis, pull out the server module by the ejector
levers until you can grasp the server module with both hands (approximately 5–6 inches).
To completely remove the server module, use your hands to slowly pull the server module out of
the chassis.
If the chassis is powered on, insert a server module filler panel into the empty slot. See
“How to
Install the Server Module Filler Panel”on page 128
.
Before You Begin
1
2
3
4
5
6
Using the Locate LED to Find the Server Module (Optional)
Sun Blade X6275 M2 Server Module Service Manual • March, 2013
32